My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MINER
>
1950
>
2300 - Underground Storage Tank Program
>
PR0504240
>
INSTALL_1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2019 9:26:42 AM
Creation date
11/7/2018 7:19:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1995
RECORD_ID
PR0504240
PE
2361
FACILITY_ID
FA0006136
FACILITY_NAME
QUICK TRUCK REPAIR
STREET_NUMBER
1950
Direction
E
STREET_NAME
MINER
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
15308006
CURRENT_STATUS
02
SITE_LOCATION
1950 E MINER AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MINER\1950\PR0504240\INSTALL\1995 INSTALL .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Total Containment markets hi.i quality <br /> environmental protection products for <br /> your secondary containment needs <br /> Bulkhead Fittings Dspenser Sumps and Pans <br /> P Gyuld-n9ht Tank Sumps Double-WallUntlerground Storage <br /> Tanks <br /> Guide Specifications <br /> Short Form Structural Integrity: The outer secondary contain- <br /> The contractor shall provide the Enviroflex®Double-Wall ment system shall be of such design and materials to <br /> piping system, as manufactured by Total Containment, have sufficient strength to withstand the maximum <br /> Inc.Both the primary and secondary piping systems shall underground burial loads and tested in accordance <br /> be installed and integrity tested in accordance with the with AASHTO M294. The flexible inner primary pip- <br /> manufacturer's published installation instructions. ing system shall be capable of withstanding liquid <br /> pressure five times greater than the designed operat- <br /> ing pressures. <br /> Design:The Double-Wall Piping System shall consist of Integrity Testing: The outer secondary containment <br /> a UL/ULC listed flexible inner primary pipe contained systems shall undergo an air pressure hold test (3 to <br /> within a ULC listed flexible outer containment pipe,each 5 psi) after installation and before the final backfill. <br /> making connection within a series of surface access The flexible inner primary piping system shall be sub- <br /> containment chambers. All piping runs shall be continu- ject to 60 psi air pressure hold test prior to final back- <br /> ous, whereby there shall be no fittings or piping con- fill. <br /> nections, for either the primary or secondary contain- Monitoring Capability: The design of the secondary <br /> ment pipe which are not visible or accessible from containment system shall permit any leak in the prl- <br /> aboveground. The secondary containment piping shall mart' piping system to be detected by a leak detaction <br /> be sized to allow complete removal of the primary piping system. <br /> without excavation. The secondary containment system Access Chambers: Surface access containment <br /> shall provide watertight containment of the tank's piping chambers shall be located at the tank containing the <br /> and its associated fittings, and the shear valve assembly tank's submersible pump and under each above- <br /> located below each aboveground fuel dispenser unit. ground fuel dispenser. These access chambers shall <br /> Product Compatibility: All the components of the meet the following requirements: <br /> Double-Wall Piping System shall be compatible with the 1. Provide product-tight tank or island connection. <br /> products to be stored. 2. Provide product-tight pipe and conduit exits. <br /> Corrosion Resistance: All components of the Double- 3. Provide sufficient strength to keep out <br /> Wall Piping System shall be made of non-corrosive surrounding backfill material. <br /> materials, or if metallic, such as the fittings and cou- 4. Made of non-corrosive, product compaai-)le and <br /> plings, isolated from corrosion causing agents. dielectric materials. <br /> 1� <br />
The URL can be used to link to this page
Your browser does not support the video tag.