My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MINER
>
437
>
2300 - Underground Storage Tank Program
>
PR0503890
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2021 10:14:54 PM
Creation date
11/7/2018 7:30:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0503890
PE
2381
FACILITY_ID
FA0006007
FACILITY_NAME
UNION OIL SS#0187
STREET_NUMBER
437
Direction
E
STREET_NAME
MINER
STREET_TYPE
AVE
City
STOCKTON
Zip
95202
APN
13924017
CURRENT_STATUS
02
SITE_LOCATION
437 E MINER AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MINER\437\PR0503890\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/2/2017 8:26:45 PM
QuestysRecordID
3373438
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROLDA <br /> RD <br /> FORM `E3': UNDER�OUND STORAGE TANK PROG AAM <br /> TANK PERMIT APPLICATION INFORMATION <br /> TANK COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. Foa <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM 1J/2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED ,r1 <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 1743 'ti )yr ale'. FARM TANK-YES 1::] N(01 7 <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY u <br /> A. OWNERS TANK ID# C.c.K B. MANUFACTURED BY: GCr A: <br /> C. YEAR INSTALLED / IF& D. TANK CAPACITY IN GALLONS, <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. W <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM Ei. G. 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL Cz <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ['i PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER{DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.P C.A S N: <br /> Mill. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A TYPE OF ❑ I DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> 19 1 STFELIIRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD WIFIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑ 5 CONCRETE ❑ B POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR F—] 1 RUBBER LINED ❑ 2 ALKYD LINING F73 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING ❑ 6 UNLINED ® 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR CR ASPHALT ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 RESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 (INFO TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A..04 FIBERGLASS PIPE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U B 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> y� r/ P S 1 VISUAL CHECK0 S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> kS / P 3 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> V1. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1, ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3, WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? Ll YES 7] NO <br /> THfS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> FAGENCY <br /> JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> 2OlFACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> r <br /> t <br /> PERMIT NUMBER PERMIT APrXP�ROVAL D E PERMIT EXPIRATION DATE <br /> 1 �J <br /> CHECK# PERMIT AMOUNT SURCHAR E AMT. FEE CODE RECEIPT# BY: <br /> pRM B(a-7-m) THIS FORM MUST BE ACCOMPANI A FACILITY/SITE APPLICATION, FOR M `A',UNLESS A..� RENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.