UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> -VI.PIPING CONSTRUCTION(Cpeck ap thatapplyj <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ❑ 1 PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY ❑ 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY <br /> CONSTRUCTIOW ❑ 1. SINGLE WALL ❑ 3. LINED TRENCH ❑99. OTHER ❑ I. SINGLE WALL ❑95. UNKNOWN <br /> MANUFACTURER ❑ 2. DOUBLE WALL ❑95. UNKNOWN ❑ 2. DOUBLE WALL ❑99. OTHER <br /> MANUFACTURER MANUFACTURER <br /> ❑ 1.BARE STEEL ❑ 8. FRP COMPATIBLE WI 100%METHANOL ❑ 1. BARE STEEL ❑ S. FRP COMPATIBLE WI 100%METHANOL <br /> MATERIALS AND ❑ 2, STAINLESS STEEL ❑ T GALVANIZED STEEL ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION ❑ 3. PLASTIC COMPATIBLEWTH CONTENTS 095. UNKNOWN ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑ 8. FLEXIBLE(HOPE) 099. OTHER <br /> ❑ 4. FIBERGLASS ❑ 8. FLEXIBLE(HDPE) 099. OTHER ❑ 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br /> ❑ 5. STEELW/COATING ❑ 9. CATHODIC PROTECTION ❑ 5. STEEL W/COATING ❑95. UNKNOWN <br /> 'Al.PIPING LEAK DETECTION(Checkattthat appy) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING <br /> PRESSURIZED PIPING(Check as that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION.AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION AUDIBLE AND VISUAL ALARMS <br /> ALARMS ❑ 2. MONTHLY 02 GPM TEST <br /> ❑ 2. MONTHLY 02 GPM TEST <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPM) <br /> ❑ 3.ANNUAL INTEGRITY TEST to 1 GPM) ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS', CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM.TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST to I GPH) ❑ e. TRIENNIAL INTEGRITY TEST(Ill GPM) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING)'. <br /> ❑ 7. SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOW'. GRAVITY FLOW(Check an that appy): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPM) ❑ B. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIALINTEGRITY TEST(0 1 GPM) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that appy): PRESSURIZED PIPING(Check all that appy) <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10.CONTINUOUS TURBINE SUMP SENSOR WATH AUDIBLE AND VISUAL ALARMS AND(&eck one) <br /> (Check ane) <br /> ❑ c. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ It AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> ❑ c. NOAUTO PUMP SHUTOFF ❑ c. NOAUTO PUMP SHUT OFF <br /> ❑ 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)WITH FLOW SHUT OFF OR ❑ 11.AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12 ANNUAL INTEGRITY TEST to 1 GPM) ❑ 12. ANNUAL INTEGRITY TEST(0 1 GPM) <br /> SUCTIONIGRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> ❑ 13. CONTINUOUS SUMP SENSOR AUDIBLE AND VISUALALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check ea that appy) EMERGENCY GENERATORS ONLY(Check as that appy] <br /> ❑ 14. CONTINUOUS SUMP SENSORVATHOUT AUTO PUMP SHUT OFF+AUDIBLE AND ❑ 14. CONTINUOUS SUMP SENSOR WTHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUALAIARMS ALARMS <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)WITHOUT FLOW SHUT OFF OR ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST) <br /> RESTRICTION <br /> ❑ 18. ANNUAL INTEGRITY TEST(0.1 GPM) ❑ 18. ANNUAL INTEGRITY TEST(0.1 GPM) <br /> ❑ 17. DMLYVISUALCHECK ❑ 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br /> DATEINSTALLEO ❑ 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS Cl 5. TRENCH LINER I MONITORING <br /> ❑ 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER-AUDIBLE AND VISUAL ALARMS B. NONE <br /> UL OWNERIOPERATOR SIGNATURE <br /> I certify that Ne inronnabon provided herein is bus and accowta to Na bast of MY IcKW 110 <br /> SIGNATURE OF OWNE WOPERATOR DATE <br /> NAME OF OWNERIOPERATOR(Pont) TITLE OF OWNER C)PERATOR <br /> Pamlit Nnmbef(For local we only) Permit Approved fPo hocal use only) Perms Expiration 0ete(Forlocal use only) <br /> CUPAFORM(4199) • • Formerly SVVRCB Farm B <br />