Laserfiche WebLink
VIED PROGRAM CONSOLIDATED FOJP <br /> ! TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> V1.PIPING CONSTRUCTION(G�eck an that ap I) Pae of <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE D 1.PRESSURE [12.SUCTION ❑3.GRAVITY 45a. 111 PRESSURE C 2.SUCTION C 3.GRAVITY 459, <br /> CONSTRUCTION/ D 1.SINGLE WALL C 3.LINED TRENCH C 99.OTHER 460. C 1.SINGLE WALL C 95.UNKNOWN 462. <br /> MANUFACTURER <br /> [12.DOUBLE WALL ®95.UNKNOWN ❑2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER 461. MANUFACTURER 463, <br /> ELBARE TEEL C 6.FRP COMPATIBLE W/100%METHANOL C 1.BARE STEEL D 6.FRP COMPATIBLE W/100%METHANOL <br /> ESS STEEL D 7.GALVANIZED STEEL C 2.STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> C COMPATIBLE WITH CONTENTS ®95.UNKNOWN D 3.PLASTIC COMPATIBLE W/CONTENTS C S.FLEXIBLE(HDPE) D 99.OTHER <br /> LASS D 8.FLEXIBLE(HDPE) C99.OTHER D 4.FIBERGLASS D 9.CATHODIC PROTECTION <br /> W/COATING D 9.CATHODIC PROTECTION 464. D 5.STEEL W/COATNG D 95.UNKNOWN 465. <br /> VIL PIPING LEAK DETECTION(Check.11 theta I)(A desI60n Of =MOTing p1c,lun1W l bewabmited to the]melacnc ) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> C 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP C 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br /> SHUT-OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION <br /> +AUDIBLE AND VISUAL ALARMS. +AUDIBLE AND VISUAL ALARMS. <br /> [12. MONTHLY 0.2 GPH TEST [12. MONTHLY 0.2 GPH TEST <br /> [13. ANNUAL INTEGRITY TEST(0.1 GPH) [13. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> [14. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING <br /> INTEGRITY TEST(0.1 GPH) C 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): [16. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> [17. SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW C7. SELF MONITORING <br /> [19. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> [18. DAILY VISUAL MONITORING <br /> 119 BIENNIAL INTEGRITY TEST(0.1 GPID <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR MM AUDIBLE AND VISUAL 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> ❑3. AUTO PUMP SHAT OFF WHEN A LEAK OCCURS D a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM C b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> Cc. NO AUTO PUMP SHUT OFF Cc. NO AUTO PUMP SHUT OFF <br /> 011. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT <br /> OFF OR RESTRICTION CIl AUTOMATIC LEAK DETECTOR <br /> C 12. ANNUAL INTEGRITY TEST(0.1 GPH) [112.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> [113. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS [113. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> D 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF [114. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> [115, AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW <br /> SHUT OFF OR RESTRICTION C 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> 016. ANNUAL INTEGRITY TEST(0.1 GPH) D 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> D IT DAILY VISUAL CHECK C 17. DAILY VISUAL CHECK <br /> VIII:DISPENSER CONTAINMENT. <br /> DISPENSER CONTAINIelEN'7 468. C1. FLOAT MECIIANISM THAT SHUTS OFF SHEAR VALVE D4. DAILY VISUAL CHECK 469. <br /> DATE INSTALLED [12. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS C 5. TRENCH/LINER MONITORING <br /> ❑3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ®6. NONE <br /> DISPENSER AND VISUAL ALARMS <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify that the informati ro ` e erein is nd a ate to the best of my knowledge. <br /> SIGNATURE OF OWNE E DATE:04-23_2004 azo. <br /> NAME OF OWNER/OP TOR(print): CHRISTOPHER MILLER TITLE OF OWNEWOPERATOR: AGENT FOR OWNER(AGE) 472. <br /> Permit Number(Agency use only) 473 1 Permit Approved By(Agency use only) 474. 1 Pemut Expiration Date(Agency use only) 475. <br /> UPCF hwfwrc-b(1/99)-3/4 http://www.unidocs.org Rev.02/16/00 <br />