3 <br />NOTE: ALL METALLIC ANCHORING COMPONENTS SHALL BE SPRAYED <br />WITH A PROTECTIVE COATING TO PREVENT CORROSION. <br />PROVIDE 12' MIN. LEVEL PEA GRAVEL BED OVER BOTTOM OF <br />EXCAVATION OR ANCHOR SLAB. SET TANKS ON BED. PLACE <br />FIRST 12" LIFT EVENLY AROUND TANKS. PUSH BACKFILL <br />COMPLETELY BENEATH TANK BOTTOM, BETWEEN RIBS AND <br />UNDER END CAPS TO PROVIDE NECESSARY SUPPORT. USE <br />SAME COMPACTION PROCEDURES FOR THE SECOND 12" LIFT. <br />PROCEED WITH BACKFILL TO TOP OF TANKS WITHOUT FURTHER <br />HANDWORK <br />2,-8- <br />3'-0" <br />SECTION "1-1" - DIESEL TANK LONGITUDINAL ELEVATION - AS BUILT: <br />SCALE: 1/4" = V-0" <br />IyINFYHH:✓iV111 <br />�J >f <br />I <br />h <br />------ ----------------------------- ---------- —DT -2 <br />(DT -1 BEYOND) I '•I //\\//\\// <br />STRIKER <br />PLATE (TYP) — 'W - - / //\//\/�• <br />=III=1—III=III=III=11f=III= DEADMAN 1B"X6"X16' <br />I I_� <br />I—III=�—�—I i AS PER DETAIL "2" <br />I=I 1=1 DWC.: FS4.03 (TYP. OF 1, <br />'I I I=111- — <br />18'-0" _ 18•-0" 18•_0, J8•-0,• :.W 2•_B,• <br />71'-4" 3'-0" 16'-6" <br />2 — <br />rsso< <br />FINISH GRADE � Fss as <br />—'�— <br />IgnI <br />PROVIDE 12" MIN LEVEL EA GRAVEL BED OVER BOTTOM <br />EXCAVATION OR ANCHOR SLAB. SET TANKS ON BED. PLACE <br />FIRST 12" LIFT EVENL AROUND TANKS. PUSH BACKFILL <br />COMPLETELY BENEATH TANK BOTTOM, BETWEEN RIBS AND <br />UNDER END CAPS TO PROVIDE NECESSARY SUPPORT USE <br />SAME COMPACTION PROC DURES FOR THE SECOND 12" LIFT. <br />PROCEED WITH BACKFILL TO TOP OF TANKS WITHOUT FURTHER <br />HANDWORK <br />SECTION "2-2" - GASOLINE TANK LONGITUDINAL ELEVATION - AS BUILT: <br />SCALE: 1/4" = 1'-0" <br />15'-0" <br />WITH <br />ow <br />2'-3" <br />FINISH GRADE <br />DETAIL <br />.• aow <br />0 <br />i <br />h <br />y % <br />12 MIN <br />DEADMAN 18"X8" 18') <br />AS PER DETAIL "2" <br />FS4.03 (TYP. OF 12) <br />16'-6" 1 3'-0" <br />PROVIDE 12" MIN. LEVEL PEA GRAVEL BED OVER BOTTOM OF <br />EXCAVATION OR ANCHOR SLAB. SET TANKS ON BED. PLACE <br />FIRST 12' LIFT EVENLY AROUND TANKS. PUSH BACKFILL <br />COMPLETELY BENEATH TANK BOTTOM, BETWEEN RIBS AND _ <br />UNDER END CAPS TO PROVIDE NECESSARY SUPPORT USE <br />SAME COMPACTION PROCEDURES FOR THE SECOND 12' LIFT. <br />PROCEED WITH BACKFILL TO TOP OF TANKS WITHOUT FURTHER <br />HANDWORK <br />SECTION "3-3" - GASOLINE AND DIESEL TANKS SIDE ELEVATION - AS BUILT: <br />SCALE: 1/4" = V-0" <br />STRIKER <br />PLATE (TYP.) <br />-III—III—III—III III—IT1= — — (DEADMM ANN12"XIZ XN <br />(—III—III—III— I =T—I AS PER DETAIL "1" i <br />_ DWG.: FS4.03 <br />–III— III III III—I �" (TYP. OF 2 EACH SIDE) <br />i-Ill=L <br />30'-6" 3'-0" 15'-0" <br />F5903 G5903 <br />APPROVED JYPE FILTER <br />FABRIC OR POLYETHYLEI <br />EXCAVATIO LINER <br />FUEL., <br />SOLUTION S- <br />12340 Santa Monica Blvd. Suite 133 <br />Los Angeles, CA 90025 <br />310/207-8548 <br />Peterson Hydraulics, Inc. <br />1653 W. EI Segundo Blvd., Los Angeles, CA 90249 <br />Phone: (310) 323.3155 Fax: (310) 323-3606 <br />License# 631515 www.Detersonhyd.com <br />"Providing Service To The Vehicle Service Industry" <br />KEY PLAN <br />FIRE DEPARTMENT <br />SUBMITTAL <br />REVISION BY DATE <br />m AS BUILT DRAWINGS P.H. 081715 <br />SAN JOAQUIN RTD <br />SAN JOAQUIN RTD REGIONAL <br />TRANSIT CENTER <br />UNDERGROUND FUEL TANKS <br />ELEVATIONS - AS BUILT <br />133023.00 <br />AS NOTED <br />I� 17 APRIL, 2014 <br />NORTH FS4.02 <br />x <br />K <br />4 HOLD T PS�WITH ) <br />o� o <br />TURNBUCI2E FOR 10,000 1 <br />Q(GALLON GASOLINE TANK <br />HOLD DOWN STRAPS WITH <br />"3"%///// <br />RNBUCKLE PER DETAIL <br />"FS4.03" <br />I I <br />VAAVAA\ <br />O <br />l <br />12" MIN. <br />STRIKE PLATE ( <br />EAC Y TANK) <br />G <br />/ I <br />(DEADMAN12X12 X <br />n <br />w <br />- AS PER DETAIL "1" <br />k DWC.: FS4.03 <br />YP. O. F 2EACH S <br />ITT <br />SII <br />6 Z4 <br />I II <br />AS PER <br />DETAIL "2' <br />I III III=I I =III III=I <br />f0' <br />C FS4.03 <br />6" <br />3'-0' <br />-I III I I I III III—I 1 <br />2'-0.. 2,_0.. <br />B, 0.. <br />3'-0„ <br />15._0" <br />29'-0" <br />13'-6" <br />13'-3" <br />APPROVED JYPE FILTER <br />FABRIC OR POLYETHYLEI <br />EXCAVATIO LINER <br />FUEL., <br />SOLUTION S- <br />12340 Santa Monica Blvd. Suite 133 <br />Los Angeles, CA 90025 <br />310/207-8548 <br />Peterson Hydraulics, Inc. <br />1653 W. EI Segundo Blvd., Los Angeles, CA 90249 <br />Phone: (310) 323.3155 Fax: (310) 323-3606 <br />License# 631515 www.Detersonhyd.com <br />"Providing Service To The Vehicle Service Industry" <br />KEY PLAN <br />FIRE DEPARTMENT <br />SUBMITTAL <br />REVISION BY DATE <br />m AS BUILT DRAWINGS P.H. 081715 <br />SAN JOAQUIN RTD <br />SAN JOAQUIN RTD REGIONAL <br />TRANSIT CENTER <br />UNDERGROUND FUEL TANKS <br />ELEVATIONS - AS BUILT <br />133023.00 <br />AS NOTED <br />I� 17 APRIL, 2014 <br />NORTH FS4.02 <br />