My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_1993
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
3023
>
2300 - Underground Storage Tank Program
>
PR0231192
>
REMOVAL_1993
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 4:25:26 PM
Creation date
11/7/2018 8:55:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1993
RECORD_ID
PR0231192
PE
2381
FACILITY_ID
FA0003864
FACILITY_NAME
GOLDEN BAY FENCE PLUS IRONWORKS
STREET_NUMBER
3023
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15702006
CURRENT_STATUS
02
SITE_LOCATION
3023 E MYRTLE ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\M\MYRTLE\3023\PR0231192\REMOVAL 1993 .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN r�UNTY PUBLIC HEALTH SERVICES/ENVIRONMENTAL HE"TH DIVISION <br /> I GST WORKSHEET FOR SITE CLOSURE EVALUATION DATE <br /> PNAMEF FACiL1TY �� SWEEPS CODEj- r ve .�-- <br /> S ii a /.yL f!_2� TANKIDIZE ,, FUEL TYPE <br /> 11. GENERAL SITE HISTORY <br /> f , <br /> Is permit current? Yes No ermit # Facility Status Code Doc.Soil/GW Cont Yes No <br /> Number of Tanks at facility f' Age of Tanks(if available) Type of Tank Steel Fbrgl Sngl Dual <br /> 111, TANK HISTORY <br /> Was Tank tested? Yes No Failed precision test ? Yes No If yes, give date(s) <br /> Was a repair made to the tank system? Y..F No 71f yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil samples analyzed? Yes No BTXE TPH-G TPH-01 17 <br /> EDB <br /> of failure/discharge catastrophic long-term leakage overfill unknown other: <br /> IV. REMCVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soii Samples Received Yes No Depth to Gro ursd Water s! Ref/Year Gl Average Annual Precipitation A= 14 10-25 <br /> On-Site Wells) Yes No Number & Type Irr Dom Pub --- <br /> S Score S Score S ficore <br /> Distance to WeLL(s) from Tank ft; ft; ft C 10 pts C 9 pts C j 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R ` condition <br /> V. Site Feature - Leaching Potential Analysis 3�() �/0 c/� E is met E is met E is met <br /> Minimum Depth to groundwater from the Soil Sample (feet) fl C, >100 51-100 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) None . Unknown Present <br /> Average Annual Precipitation (inches) xxxxxx <10 9 10-25 xxxxxxx 26-40\2 <br /> Man-Made conduits which increase vertical migration <br /> of leachate (i.e., <br /> septic systems, water wells, ponds) None j Unknown Present <br /> Unique site features: Recharge area, coarse soil, nearby wells. At least More than <br /> xxxxxxLNonefi one one <br /> COLUMN TOTALS>>>TOTAL POINTS ) <br /> Sample Result: (B T X OR E) RANGE OF TOTAL POINTS 49 pts or more x/41 - 48 pts 40 pts or less <br /> B TX E F B JT X E <br /> MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. 1. NA\3 <br /> Sample Result: GASQLINE 1000 100 10 <br /> MAXIMUM ALLOWABLE TPH LEVELS (PPM) <br /> TPH DIESEL 10,000 1000 100 <br /> FOOTNOTES: ***If documented soil and/or ground water contamination is present, don -til to the Leaching potential <br /> analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> \2 1f precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> VI. STAFF RECOMMENDATION/CONCLUSION <br /> 1. Are BTX & E or TPH Concentrations > Allowable Levels *Yes No f <br /> * r to Site Mitigation for Evaluation r �- <br /> 2. Recommend Site Closure Yes No If Yes, Refer g <br /> VII. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES NO REFERRED TO SITE MITIGATION FOR EVALUATION YE5 NO <br /> DATE REFERRED / / DATE CLOSURE LETTER MAILED <br /> NAME OF <br /> EVALUATOR <br /> EH 23 80 (UGTWKSHT)\5/90 <br />
The URL can be used to link to this page
Your browser does not support the video tag.