Laserfiche WebLink
"i1a/lnna 14:24 4b40138 ENVIRONMENTAL HEALTH PAGE 05 <br /> MINIMUM VERIFICATION LABORATORY ANALYSIS <br /> OXYGEN <br /> TANK TANK TPH-G TPH-D BTX&E CL HC TOTAL MTBE ATES nlrrnt• PCB <br /> # CONTENTS 8015 8015 8020 8010 LEAD 8020 (MTBE. ICAP/ 8270 <br /> 8260 8260 8260 8240 7420 8260 TBA,DIPE, AES or 8080 <br /> 8260 7421 SBS' AA <br /> TAME) <br /> azbD <br /> LEADED GAS X X X X <br /> UNL GAS X X X <br /> DIESEL X X <br /> KEROSENE X X X <br /> UNK FUEL X X X X X <br /> PROD.OIL X X X <br /> CHLOR X <br /> SOLVENTS X X <br /> NONCHLOR X <br /> SOLVENTS X X <br /> WAST£\ —T X X <br /> USED OIL X X X X X <br /> Ali analysis methods are the designated EPA methods described in EPA SW 846,Third Edition. "Those methods not found in SW 846 are <br /> specifically noted below. Refer to the "SWRCB LUFT Field Manual", Appendix D (B),Table 3-5 on page A20 for minimum detectior <br /> limits for motor vehicle fuel (gasoline and diesel). Refer to "Tri-Regional Board Staff Recommendations for Initial Evaluation am <br /> Investigation of UST's"for the waste and motor oil minimum detection limits. Detection Limits that remain below the MCL,$TLC or <br /> Allowable Limit of the contaminant in question will be accepted,however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> TPH-G Total Petroleum Hydrocarbon,Gasoline,GC/FID(5030)8015 mod or GC/MS 826D <br /> TPH-D Total Petroleum Hydrocarbon,Diesel,GC/FID(3550),8015 mad or GC/MS 8260 <br /> BTX&EBenzenc,Toluene,Xylene&Ethyl Bcnzenc,OC/P1D 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon,GC/HSD 8010,GC/MS 8240 or 8260 <br /> TOTAL LEAD Total Iced,AA 7420, AA 7421 or ICP-AES 6010 <br /> OXYGENATES MTBE,ETBE,TAME,DIPS,&TBA GCWS 8260(For MTBE screan only you may use 8020) <br /> METALS ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption Spectrometry 7000. Metals: <br /> Cadmium,Chromium III and VI,Lead,Zinc and Nickel. <br /> PCB Polychlorinated Biphenyls,GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample prapamtion,extraction method <br /> Method 5030 Purge and bap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene,benzene-fee solvents are to be used. Fused capillary columns an preferred to packed columns;a <br /> packed column may be used as a"first cut"with"dirty"samples or once the hydrocarbons have been characterized and proper QA/QC is followed. For <br /> drinking water sources,EPA recommends that the 300 series for voladic organic should be used in preference to the 600 series because the detection <br /> limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal contamination may require further analysis.PHS-END <br /> recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 05109/00) <br /> 5 <br />