Laserfiche WebLink
OPERATING GUIDELINES / CONVERSION FORMULAS / SUPPLEMENTAL DOCS <br /> 19.4.3. If the delivery vehicle uses pumps to fill the 20. CONVERSION • ' <br /> tank,precautions must be taken as outlined in 20.1. Use this as a guide if a dimension does not have a <br /> the"Filling Tanks"section of this manual. metric conversion printed. <br /> 19.4.3.1. Product delivery from vehicles using LENGTH WEIGHT <br /> pressure in the ullage is not allowed. mm = millimeters kg = kilogram <br /> 19.4.4. The tank's venting system must be adequately . 1" = 25.4 mm l lb= 0.454 kg <br /> sized to ensure that atmospheric pressure is . 1' = 304.8 mm <br /> maintained at all times,including when filling PRESSURE CAPACITY <br /> and emptying the tank. kPa = kilopascals L = liters <br /> 19.4.4.1. For tanks with inlet or outlet piping that 1 psi = 6.894 kPa 1 gal = 3.785 L <br /> will result in pressure at the tank top,the <br /> pressure should be limited to 1 psig. 21. SUPPLEMENTAL DOCUMENTS <br /> 19.5. For UL/ULC tanks,The Petroleum Equipment 21.1. Supplemental documents,which may apply <br /> Institute has published several recommended to specific installations and/or conditions, <br /> practices(PEI/RP900 and PEI/RP1200)that are available upon request from Containment <br /> address proper maintenance,inspection and Solutions Technical Support. <br /> testing of overfill prevention equipment.Tank <br /> owners should obtain a copy of the documents Single-Wall Tank Sump Installation Instructions <br /> at http•//www.pei.org.In addition,the Fiberglass (Pub. No.INST 6030) <br /> Tank and Pipe Institute has published a white • Double-Wall Tank Sump Installation <br /> paper on the adverse effects of using vent Instructions(Pub.No.INST 6034) <br /> restriction devices such as ball-float valves and • Access Riser Installation Instructions w/ <br /> the unintended consequences that may occur see Adhesive Channels(Pub.No.INST 6056) <br /> http://www.fiberglasstankandpipe.com. • Standard Hold Down Strap Anchor System <br /> 19.6. The owner must make sure the tank is properly (Pub.No.INST 6062) <br /> vented at all times as described in the venting • Split Strap Anchor System <br /> section of this manual.Vent piping should be (Pub.No.INST 6063) <br /> properly installed and unobstructed. • Wire Rope overTankTop <br /> 19.7. Do not use ball float valve for overfill protection. (Pub. No.INST 6047) <br /> 19.8. For tanks with vapor recovery systems,the • Fiberglass Tanks Shipping into Canada <br /> pressure or vacuum cannot exceed 1 psig. Installation Instructions <br /> 19.9. It is strongly recommended that the tank be (Pub.No.INST 6043-CAN) <br /> gravity filled and that the owner regularly inspect • Urea DEF Installation Instructions <br /> the automatic shut off device or vent restriction (Pub.No.INST 6052) <br /> device for proper operation. • Triple-Wall Tank Installation Instructions <br /> 19.10. Proper grounding of the drop tube/fill line is (Pub.No.INST 6045) <br /> important to prevent static discharge during . NYC Special Installation Instructions <br /> filling. (Pub.No.INST 6008) <br /> 19.11. If flooding may occur,precautions should be • Fiberglass Oil/Water Separator Tank <br /> taken to prevent tank float and equipment Installation and Start-Up Instructions <br /> damage.See EPA"Underground Storage Tanks (Pub. No.OWS 2013) <br /> Flood Guide".See Ballasting section in these Alternate Backfill Above TankTop <br /> instructions should ballasting tanks be required. Installation Instructions(Pub.No.INST 6014) <br /> 19.12.Containment Sumps. Manway . Berm Installation Instructions <br /> Extensions,and Access Risers (Pub.No.6022) <br /> 19.12.1. Tank owner must leak test the collar and • Bottom Sump Installation Instructions <br /> containment sump after any damage, (Pub.No.INST 6044) <br /> repairs,modifications or to meet regulatory • Flexible Connector Specification <br /> requirements. (SPEC 9005) <br /> 19.12.2. UL/ULC sumps must be continuously • Brine Monitoring Fluid MSDS Sheet <br /> monitored with an electronic leak detector for (Pub.No. 15002) <br /> potential spills or leaks. Lifting Tanks with Slings (Pub.No.6021) <br /> 19.12.3. Gaskets are consumable products which will <br /> have to be replaced periodically or when it <br /> shows a leak during a tightness test. <br /> 26 <br />