Laserfiche WebLink
C. Dimensional Requirements: C. Flanged Manways <br /> (refer to Containment Solutions literature on gallonage): 1. The standard manway is 22'ID.The 30"and 36"ID manways are <br /> 1. Nominal capacity of the tank shall be_gallons. optional. <br /> 2. Nominal outside diameter of the tank shall be_feet. 2. All manways will be furnished complete with U.L. listed gaskets, <br /> =1 <br /> 3. Nominal overall length of the tank shall be feet. bolts and covers. <br /> D. Monitoring Capabilities: 3. Location-see standard tank drawings(pages 15-22). o <br /> 4. The steel manway cover is standard with 4" diameter NPT 0 = <br /> 1. Tanks shall have a space between the primary and secondary Amanway covers with an even number of fittings will <br /> shell walls to allow for the free Flaw and containment of all leaked fittings.22" a <br /> product from the primary tank. be placed on an 8"radius.Manway covers with an odd number a <br /> of fittings will have one fitting centered and the remaining <br /> 2. The following continuous monitoring conditions shall be fittings placed on an 8" radius. 30" manway cover fittings are ° GO <br /> compatible with the cavity between the inner and outer tanks: standard 12"radius.36"manway cover fittings are standard 15" <br /> • Vented to atmosphere radius. <br /> • Vacuum-1.5 psi maximum(3"mercury) 5. Manway risers 48" in diameter and 42" high will be supplied to <br /> • Positive air pressure(3 psi maximum) provide access to the manway lid.A 24'x 24"galvanized street <br /> • External hydrostatic pressure-7'maximum groundwater head box with a cover must be provided by contractor for at-grade <br /> pressure over tank top installation. <br /> 3. Tanks 6' diameter and larger shall have an integrally mounted 6. Fiberglass manway extension tubes 24"long will be provided for <br /> reservoir* installed on the tank for optional hydrostatic the manways. <br /> monitoring. The reservoir shall be constructed of fiberglass D. Fill Tubes - Fill tubes of appropriate design will be supplied by <br /> reinforced plastic materials and warranted for 30 years against contractor, <br /> failure due to internallexternal corrosion and when properly <br /> installed,against structural failure(same as tank warranty). E. Hydrostatic Monitor Accessories: <br /> 4' diameter DWT-6 Type II tanks do not include a fiberglass 1. Brine Antifreeze <br /> reservoir.A 4"diameter riser pipe screwed into the 4"diameter Brine Solution Designation: BAS-30 <br /> annular space fitting will serve as the reservoir. Chemical Composition: 30%+ calcium chloride, 1% to 3% <br /> 4. Tank shall be designed with one 4'fitting that will access the tank potassium chloride, 1%to 2%sodium chloride, Balance water <br /> bottom between the primary and secondary walls (annular Visual Appearance: Green in color,Odorless fluid <br /> space). Specific Gravity @ 60"F: 1.272-1.317 <br /> 5. The double-wall tank monitor shall be capable of detecting a Factory installed on tanks 30,000 gallon and under. Bulk brine <br /> breach in the inner and/or outer tank under the following installed jobsite installed on 35,000 gallon and 40,000 gallon tanks. <br /> conditions: 2. Reservoir Sensor - The FHRB 810 reservoir sensor is <br /> a. When the inner tank is empty. specifically designed for installation in the reservoirs of CSI <br /> b. When the inner tank is partially or completely full and the double-wall tanks. The components of the sensor are <br /> groundwater table is below the tank bottom. compatible with CSI supplied brine solutions.The sensor is also <br /> compatible with any other control panel that accepts normally <br /> c. When the inner tank is partially or completely full and the tank open or closed switches.The sensor provides two alarm points: <br /> is partially or completely submerged in groundwater. high brine and low brine.The sensor can be wired to a control <br /> 6. The leak detection performance of the hydrostatic monitoring panel to provide only a single alarm(not distinguishing between <br /> system shall be tested and verified by a qualified independent high or low alarms) or it can be wired to report both alarm <br /> consultant to detect leaks as small as 0.10 gallons per hour conditions. <br /> within a one month period. 4. Tank Gauge Probe-The IPFW Series tank gauge probe shall <br /> 7. All monitoring equipment, including FRP reservoirs and be capable of continuously monitoring liquid levels and <br /> electronic controls,shall be UL listed or accepted. detecting water in hydrocarbons at the bottom of tanks. The <br /> 8. If hydrostatically monitored, any solution used in the tank probe shall be compatible with the liquid it is intended to be <br /> annular space shall have UL approval for compatibility with the submerged in and sized properly to fit into the tank without <br /> tank and be a contrasting color to the tank surface to facilitate damaging the tank during installation or operation. The tank <br /> visual inspection of the tank for leaks prior to burial. gauge probe shall not be rigidly mounted in the tank. <br /> 2.02 Accessories F. Tank Sumps and Collars: <br /> A. Anchor Straps-Provide glass fiber reinforced plastic anchor straps 1. Non-Sealed FRP Tank Sump(Model NTS Series)- <br /> for each tank shown. Number and location of straps shall be as The non-sealed tank sump consists of a fiberglass reinforced <br /> specified by manufacturer. Each strap shall be capable of plastic (FRP)sump body(variable length in 12"increments, 42" <br /> withstanding a maximum load for each tank diameter as shown. or 48"ID's),an FRP reducer(42"x30'or 48"x30'ID's),and a loose <br /> 4'0 — 4,200lbs. fit FRP lid with handle. The reducer opening must be large <br /> 6'0 — 188,,000 las. enough(minimum 281 to allow for the removal of a 22"manway <br /> 8'0 — 25,000 Ibs. lid.The lid OD must be small enough to be removed through a <br /> 1 — Ibs. 36"street box.The sump body must be capable of joining to the <br /> Straps shall be standard as supplliedied bby y the tank manufacturer. 42"or 48"diameter secondary containment collar with a leaktight <br /> B. Certification Plate - Underwriters Laboratories label shall be adhesivejoint, <br /> permanently affixed to each tank. <br /> 33 <br />