Laserfiche WebLink
Veeder-Root Line Leak Application Guide <br /> TLS-350 Consoles - PLLD <br /> Hardware Required for PLLD Leak Detection <br /> PRESSURIZED LINE LEAK DETECTOR(PLLD) <br /> Order one per line. <br /> MODEL NO. ITEM <br /> 848480-003 PRESSURIZED LINE LEAK DETECTOR WITH SWIFTCHECK VALVE <br /> 848480-001 PRESSURIZED LINE LEAK DETECTOR WITHOUT SWIFTCHECK VALVE <br /> PLLD MODULES <br /> •TLS-350/TLS-350 Plus/TLS-350R Consoles- Leak Detection for up to 6 Lines <br /> One Pressurized Line Leak Detector Interface Module is required per console.Order PLLD Controller modules as required <br /> -one Controller module monitors up to 3 lines. <br /> MODEL NO. REM <br /> 330843-001 SIX INPUT PRESSURIZED LINE LEAK INTERFACE MODULE(MAXIMUM 1 PER CONSOLE) <br /> 330374-001 PRESSURIZED LINE LEAK CONTROLLER MODULE(MAXIMUM 2 PER CONSOLE) <br /> -TLS-350J Consoles-Leak Detection for up to 4 Lines <br /> One'J'PLLD Interface Module is required per console.Order PLLD Controller modules as required-one Controller module <br /> monitors up to 3 lines. <br /> MODEL NO. REM <br /> 330843-002 'J'PLLD INTERFACE MODULE (MAXIMUM 1 PER CONSOLE) <br /> 330374-001 PRESSURIZED LINE LEAK CONTROLLER MODULE(MAXIMUM 2 PER CONSOLE) <br /> PLLD PRECISION TESTING SOFTWARE MODULE <br /> Precision line leak detection capability(0.2 gph/0.1 gph) requires one SEM (Software Enhancement Module)for the console <br /> that must be ordered separately from the table below. Not required for 3.0 gph-only line leak detection capability. <br /> TLS-350/TLS-350J/ TLS-35OR <br /> TLS-350PLUS/TLS-3508 WITHOUT BIR WITH BIR <br /> TESTING OPTION (SEM P/N) (SEM P/N) <br /> ULTIMATE TESTING 330160-010 330160-110 <br /> RISK MANAGEMENT 330160-060 330160-160 <br /> BASE COMPLIANCE 330160-050 330160-150 <br /> 3.0 GPH INCLUDED- INCLUDED' <br /> 'A SEM is not required for 3 GPH-only testing. <br /> PLLD Precision Testing Frequencies <br /> ON-DEMAND(D) <br /> Testing can be initiated manually through the TLS Console. <br /> AUTO(A) <br /> Tests will run repetitively until a passing test is achieved.Once a passing test is achieved,testing will stop and recom- <br /> mence six months from the date of the last passing test. <br /> MONTHLY(M) <br /> Tests will run repetitively until a passing test is achieved.Once a passing test is achieved,testing will stop and recom- <br /> mence the first calendar day of the next month. <br /> REPETITIVE(R) <br /> Tests will run repetitively according to pre-programmed time intervals. <br /> Refer to the matrix below to determine which precision testing option best meets your needs: <br /> 8 <br />