My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Application Guide <br /> TLS-350 Consoles - PLLD <br /> Hardware Required for PLLD Leak Detection <br /> PRESSURIZED LINE LEAK DETECTOR(PLLD) <br /> Order one per line. <br /> MODEL NO. ITEM <br /> 848480-003 PRESSURIZED LINE LEAK DETECTOR WITH SWIFTCHECK VALVE <br /> 848480-001 PRESSURIZED LINE LEAK DETECTOR WITHOUT SWIFTCHECK VALVE <br /> PLLD MODULES <br /> •TLS-350/TLS-350 Plus/TLS-350R Consoles- Leak Detection for up to 6 Lines <br /> One Pressurized Line Leak Detector Interface Module is required per console.Order PLLD Controller modules as required <br /> -one Controller module monitors up to 3 lines. <br /> MODEL NO. REM <br /> 330843-001 SIX INPUT PRESSURIZED LINE LEAK INTERFACE MODULE(MAXIMUM 1 PER CONSOLE) <br /> 330374-001 PRESSURIZED LINE LEAK CONTROLLER MODULE(MAXIMUM 2 PER CONSOLE) <br /> -TLS-350J Consoles-Leak Detection for up to 4 Lines <br /> One'J'PLLD Interface Module is required per console.Order PLLD Controller modules as required-one Controller module <br /> monitors up to 3 lines. <br /> MODEL NO. REM <br /> 330843-002 'J'PLLD INTERFACE MODULE (MAXIMUM 1 PER CONSOLE) <br /> 330374-001 PRESSURIZED LINE LEAK CONTROLLER MODULE(MAXIMUM 2 PER CONSOLE) <br /> PLLD PRECISION TESTING SOFTWARE MODULE <br /> Precision line leak detection capability(0.2 gph/0.1 gph) requires one SEM (Software Enhancement Module)for the console <br /> that must be ordered separately from the table below. Not required for 3.0 gph-only line leak detection capability. <br /> TLS-350/TLS-350J/ TLS-35OR <br /> TLS-350PLUS/TLS-3508 WITHOUT BIR WITH BIR <br /> TESTING OPTION (SEM P/N) (SEM P/N) <br /> ULTIMATE TESTING 330160-010 330160-110 <br /> RISK MANAGEMENT 330160-060 330160-160 <br /> BASE COMPLIANCE 330160-050 330160-150 <br /> 3.0 GPH INCLUDED- INCLUDED' <br /> 'A SEM is not required for 3 GPH-only testing. <br /> PLLD Precision Testing Frequencies <br /> ON-DEMAND(D) <br /> Testing can be initiated manually through the TLS Console. <br /> AUTO(A) <br /> Tests will run repetitively until a passing test is achieved.Once a passing test is achieved,testing will stop and recom- <br /> mence six months from the date of the last passing test. <br /> MONTHLY(M) <br /> Tests will run repetitively until a passing test is achieved.Once a passing test is achieved,testing will stop and recom- <br /> mence the first calendar day of the next month. <br /> REPETITIVE(R) <br /> Tests will run repetitively according to pre-programmed time intervals. <br /> Refer to the matrix below to determine which precision testing option best meets your needs: <br /> 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.