Veeder-Root Q ID Liq Page 1 of 2 <br /> Issue Date: November 22,1995 <br /> Revision Date: August 23,2010 <br /> Veeder-Root <br /> TLS-300 Series,TLS-350 Series,TLS-450 Series, EMC Series, EMC Basic, Red Jacket ProMax and ProPlus with <br /> Single Stage Hydrostatic Sensor 794380-301, <br /> Dual Stage Hydrostatic Sensors 794380-302,303 <br /> INTERSTITIAL DETECTOR(LIQUID-PHASE) <br /> Detector: <br /> Output type: qualitative <br /> Sampling frequency: continuous <br /> Operating principle: Float switch <br /> Test Results: <br /> Single Stage Hydrostatic Sensor 30%by weight 50%by weight *50%by weight <br /> 794380-301 calcium chloride in water propylene glycol in water ethylene glycol in water <br /> Product Activation Height(in) 1.74 1.94 1.5 <br /> Response time(min) <1 <1 35.75 <br /> Recovery time(min) <1 <1 <1 <br /> Dual Stage Hydrostatic Sensor water <br /> 794380-302** hici1*** low*** <br /> Product activation height(in) 12.25 1.62 <br /> Response time(min) <1 <1 <br /> Recovery time(min) <1 <1 <br /> 30%by weight 50%by weight <br /> Dual Stage Hydrostatic Sensor calcium chloride in water ethylene glycol in water <br /> 794380-303 high*** low*** hs*** low*** <br /> Product activation height(in) 13.13 1.20 13.15 1.48 <br /> Response time(min) <1 <1 <1 <1 <br /> Recovery time(min) <1 <1 <1 <1 <br /> *Evaluation performed by Carnegie Mellon Institute. <br /> ** Dual Stage Hydrostatic Sensor 794380-302 was replaced by Sensor 794380-303 and is not supported by TLS-450 series console. <br /> ***The"high"and'low"refer to high and low level alarm points of dual stage hydrostatic sensors. <br /> Comments: <br /> EMC Series and EMC Basic controllers have been evaluated only for use with sensors 794380-301 and 794380-303. <br /> Evaluator reports that sensors will respond to any liquid after their thresholds are exceeded. <br /> Response times measured from trigger point,except for sensor 794380-301 with 50%by weight ethylene glycol in water,where response <br /> time also included time for liquid level to rise from bottom of a test cylinder to trigger point. <br /> Evaluator reports sensors can easily be removed,cleaned,and reinstalled after an alarm was triggered or for periodic testing. <br /> Sensors are reusable. <br /> Comparison of TLS-450 with TLS-350 series console showed comparable results when evaluated with representative sensors. <br /> Single Stage Hydrostatic Sensor 794380-301: <br /> Intended to monitor level of propylene glycol,ethylene glycol,or calcium chloride solutions in interstitial or annular space of a double- <br /> walled tank. <br /> If the brine level in the reservoir drops below the threshold of the sensor,an alarm condition is generated. <br /> The evaluation using 30%by weight calcium chloride in water was reevaluated using a different acceptable test protocol. <br /> Dual Stage Hydrostatic Sensor 794380-302: <br /> Alarm is activated if any significant gain or loss of solution occurs. <br /> Dual stage hydrostatic sensor 794380-303 has replaced this sensor and is fully interchangeable with this sensor. <br /> Vendor will discontinue production of this sensor as of December 31, 2003. <br /> Dual Stage Hydrostatic Sensor 794380-303: <br /> If brine level or propylene glycol level in reservoir drops below the threshold of low-level sensor or if any liquid rises above the threshold <br /> of high level sensor,an alarm condition is generated. <br /> Alarms are indicated by an audible alarm,displayed message on the console,printed message(if the console is equipped with a printer), <br /> and recorded as part of the console"Alarm History Report." <br /> Veeder-Root Evaluator: Carnegie Mellon Research Institute <br /> 125 Powder Forest Dr. Tel: (412)268-3495 <br /> Simsbury,CT 06070-2003 Dates of Evaluations: 12/07/92,03/16/98 <br /> http://nwgide.org/evals/veeder_root q.html 10/17/2017 <br />