My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN _J O A Q U I N Environmental Health Department <br /> COUNTY— <br /> F. SYSTEM PIPING CONTINUED: MAY 2`� 2p18 <br /> Check CC <br /> Box Section EN���ONM TMENT <br /> HEA1- <br /> HSC Piping compatible with material intended to be stored. <br /> � 252902 c t <br /> 23 CCR <br /> 2631(b) Design and construction of piping approved by independent testing or anizatlon e. . UL). <br /> Pi in , includin vent lines,slo ed toward tank(s)with minimum 1/8 inch slope per 1 foot of run. <br /> 25290.1((k)) Vapor recovery, fill riser, and vent line piping are secondarily contained. <br /> IX 25290.2(c)&(j) <br /> G. OVERSPILL/ OVERFILL PREVENTION: <br /> CheckC <br /> Box Rection <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> [X 2635(b) Manufacturer OPW Model P711-EVR <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> ❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br /> X 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> ;Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer OPW Model 71SO-410C <br /> H. CORROSION PROTECTION: <br /> Check code <br /> Box Section <br /> ,lr Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> * 23 CC ❑ Steel isolated from contact with backfill <br /> WFRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> * 2635(a)(2) ❑ Steel tank with field installed cathodic protection or impressed <br /> current <br /> Tie-downs,when used,constructed of noncorrosive material or coated steel. <br /> 7 of <br />