INSTALL 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRESSURE TESTING SIDEBAR <br /> Single-Wall (or Primary)Tank 4.If there is no monitoring fluid on Dry Double-Wall <br /> eithertheinteriorortheexteriorof Multicompartment Tank <br /> 1.Pressurize the tank. any compartment,backfill the tank Not Under Vacuum <br /> 2.Check threaded orflanged joints to the top of the tank. <br /> for problems with the tank. 5.After the tank is backfilled to the top 1.Install a test manifold in the base tank <br /> 3.Soap the entire exterior of the tank of the tank,it may be pressure tested and in each end compartment. <br /> (not applicable for a double-wall tank), as in Single-Wall(or Primary)Tank 2.Pressurize the base tank and the end <br /> including all service fittings and steps 1-6. compartment(s)as in a Single-Wall <br /> manways when present. NOTE:For multicompartmenttanks, (or Primary)Tank steps 1-4. <br /> 4.Hold and monitor the pressure follow these instructions to test ea ch 3.Pressurize the interstitial space using <br /> for a minimum ofIhour. tmentthe quick-disconnect assembly and follow <br /> compartment.5.Carefully release the pressure from the tank. instructions for Dry Double-Wall Tank <br /> 6.Remove the test manifold and replace Not UnderVacuum steps 3-6. <br /> the protective covers in the service fittings. Dry Double-Wall Tank 4.Afterthe tank is backfilled to the top <br /> Not Under Vacuum of the tank,it may be pressure tested <br /> Wet Double-Wall Tank as in Single-Wall(or Primary)Tank <br /> 1.Testthe primary tank as in Single-Wall steps 1-6. <br /> NOTICE (or Primary)Ta nk steps 1-4. <br /> Never pressurize a wet interstitial space. 2. Use the quick-disconnect assembly Dry Double-Wall Tank <br /> Doing so could result in damage to the to pressurize the interstitial space. Under Vacuum <br /> primary tank and/or tank failure. 3.Soap the entire exterior of the tank. <br /> 4.Hold and monitorthe pressure in 1.Follow the pass/fail criteria shown <br /> 1.Check the level of the monitoring fluid the interstitial space for a minimum in section 4.9.4for double-wall <br /> in the reservoir. of 1 hour. tank shipped undervacuum <br /> 2.Visually checkthe interior and the 5.Carefully release the pressure from to determine if preinstallation <br /> exterior of each compartment for the primary tank. d. <br /> the presence of monitoring fluid. 6.Remove the test manifold and replace pressure testing is require <br /> 2.Afterthe tank is backfilledd. the top <br /> 3.If the monitoring fluid isnotatthe the protective covers in the service fittings. of the tank,it may be pressure tested <br /> proper level,and/or monitoring fluid 7.Afterthe tank is backfilled to the top as in Single-Wall(or Primary)Tank <br /> is found on eitherthe interior orthe of the tank,it may be pressure tested steps 1-6. <br /> exterior of any compartment,contact as in Single-Wall(or Primary)Tank <br /> the manufacturing facility that shipped steps 1-6. <br /> the tank. <br /> NOTE:All UL-and ULC-label and potable watertanks must be pressure tested after backfill is brought close to the top of the tank. <br /> 4:TESTING DURING INSTALLATION 19 <br />