My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5.5.1.5.Contamination can be avoided by doing one of the following: NOTICE <br /> • ballast the tank with a liquid compatible with the product being Al I internal piping must beat least 4 inches[10cm]from <br /> stored OR the tank bottom.Failureto follow this notice could result <br /> • clean the tank after ballasting to eliminate any contaminating product in damage to the tank and/or surrounding property. <br /> A WARNING NOTICE <br /> Inertthe tank and use inert gases(not air)to pressure test All metal fittings and other metal components must be coated <br /> a tank that contains or has contained flammable or combustible to protect against corrosion.Failure to do this could result in <br /> liquids or vapors.Failure to follow this warning could result damage to these parts,the tank and/or surrounding property. <br /> in an explosion,and could result in death or serious injury. 7,1,2.Fortanks equipped with manways,see table and relevant figure <br /> A WARNING in Piping Sidebar to determine the correct length for internal piping. <br /> If flammable or combustible product is used as ballast,exercise 7,1,3. For tanks equipped with access openings,see table <br /> special care in handling.Safeguard against sparks,fire or product and relevant figure in Piping Sidebar to determine the carred <br /> spills.Failure to follow this warning could result in a fire or an and re evanfor internal piping. <br /> i pP p <br /> explosion,and could result in death or serious injury. <br /> 7.2.EXTERNAL PIPING <br /> 6: POSTINSTALLATION TESTING A WARNING <br /> The tank must be isolated from all piping when the external <br /> 6.1. PRESSURE TESTING TANKS piping is being pressure tested.The test pressures for external <br /> piping could cause tank failure,and could result in death <br /> 6.I.I.Ifthe tank isawater/wastewater tank equipped forpressure or serious injury. <br /> testing,follow the procedures in the Preinstallation Testing Instructions <br /> for Wate r/Wastewater Tanks Factory-Equipped for Pressure Testing 7.2.1•When extending monitoring or vapor-recovery piping <br /> supplement.See the introduction for information on how to obtain to the surface,make sure the at-grade fittings are different from <br /> this supplement. any fill fittings and will notaccept standard fill hoses. <br /> 6.1.2.All UL-label,ULC-label and potable watertanks must be NOTICE <br /> pressure tested after backfill is brought close to the top of the tank. All connections to the tank must be flexible.Provisions must be <br /> made to accommodate movement and misalignment between <br /> 6.1.3.If the tank is ballasted with water,the tank can be pressurized the piping and the tank.Failure to do this could result in damage <br /> for pressure testing.See Pressure-Testing Sidebar. to the tank and/or surrounding property. <br /> 6.2.OPTIONAL HYDROSTATIC TESTING 7.3.VENTING TANKS <br /> 6.2.I.This optional test istypically used forwaterorwastewater A WARNING <br /> tanks that are not pressure-testable due to the accessories on the tank. All underground tanks/compartments shall be adequately <br /> 6.2.2.Use the following procedure for this test: vented to prevent the development of vacuum or pressure <br /> • Seal off the influent and effluent piping,and any fittings that when filling or emptying the tank.Failure to properly vent <br /> are below the tank top with watertight caps or plugs. a tank or compartment could cause tank failure,and could <br /> • Fill the tank with water to a level that is 3 inches[7.6 cm]into result in death or serious injury. <br /> the access openings afterthe backfill is at least 75 percent of the 7.3.I.The primary tank isdesigned tooperate atatmospheric <br /> way up the tank. pressure. <br /> • Letthe waterstand in the tank fora minimum of 1 hour(or longer <br /> if required by applicable local codes). 7.3.2.The tank's venting system must be adequately sized to ensure <br /> • Allow sufficient time so that the water temperature stabilizes. that atmospheric pressure is maintained at all times,including during <br /> • If the water level drops,check to see that plugs or caps sealing off filling and emptying of tank. <br /> the piping are tight.Then add more water to fill air voids and return 7,3.3.Whenever installing overfill protection,such as an alarm,an <br /> the water level back to the standard testing level. automatic shut-off device(fill pipe Flappervalve)or a vent-restriction <br /> • If the water level does not stabilize,contact the manufacturing facility device(ball-float valve),follow the instructions provided by the manu- <br /> that shipped the tank. facturer of the overfill-protection device and consult the authority having <br /> jurisdiction to determine the level at which the overfill protection should <br /> 7: PIPING, VENTING AND operate. <br /> • Some jurisdictions do not allow ball-float valves. <br /> CONTAINMENT SUMPS • Consult applicable codes and regulations. <br /> 7.1.INTERNAL PIPING A WARNING <br /> Vent-restriction devices for overfill should not be installed if <br /> 7.1.1.All piping must conform to all applicable codes and standards. owner/operator will allow pump-or pressure-filling of tank. <br /> Failure to follow this warning could cause tank failure, <br /> and could result in death or serious injury. <br /> 5: INSTALLING TANKS/6: POSTINSTALLATION TESTING/7: PIPING,VENTING AND CONTAINMENT SUMPS 23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.