Laserfiche WebLink
�a 111N C <br /> Q' , ° , $QN�IOQQU� N Environmental Health Department <br /> Linda Turkatte, REHS, Director <br /> Greatnessrows here. <br /> 9 Kasey Foley, REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellan,REHS <br /> Jeff Carruesco, REHS, RDI <br /> Rodney Estrada,REHS <br /> Willy Ng, REHS <br /> Muniappa Naidu, REHS <br /> December 19, 2017 <br /> JR BEARD <br /> LHB and ASSOCIATES. <br /> 867 PACIFIC STREET, SUITE 120 <br /> SAN LOUIS OBISPO, CA 93401 <br /> RE: Chevron Gas Station, 1490 S. Main St. Manteca, CA 95337 SR0076222 <br /> The San Joaquin County Environmental Health Department(EHD) has completed the review of the application for <br /> a permit to install a new underground storage tank (UST) system at the above noted address. The proposed <br /> underground storage tank(UST)system will consist of one 20,000 gallon 87-octane gasoline UST and one 20,000 <br /> gallon split UST (split between 8,000 gallons of 91-octane gasoline and 12,000 gallons of diesel). <br /> The permit has been approved with the following conditions: <br /> 1. Contact the Lathrop-Manteca Fire District, the San Joaquin Valley Air Pollution Control District, and the <br /> San Joaquin County Community Development Department for applicable permits. <br /> 2. Any changes shall be submitted to the EHD for approval prior to commencing work. All new submittals <br /> supersede the previous ones <br /> 3. Qualified installers must possess or work under the direct and personal supervision of an individual <br /> physically present at the work site, at all times while work is being performed, who possesses all of the <br /> following: <br /> • One of several permissible valid, current contractor's licenses issued by the Contractors State <br /> License Board (may be issued to the installation company), and <br /> • A valid, current UST Installation/Retrofitting certificate issued by the International Code Council <br /> (ICC), and <br /> • A valid, current certificate of training from the manufacturer(s) of the component(s) being installed, <br /> additionally, <br /> • Each person installing or testing any component must hold a certificate of training from the <br /> manufacturer of that component. <br /> 4. Qualified service technicians must possess or work under the direct and personal supervision of an <br /> individual physically present at the work site, at all times while work is being performed, who possesses <br /> all of the following: <br /> • One of several permissible valid, current contractor licenses issued by the Contractors State <br /> License Board (may be issued to the installation company), and <br /> • A valid, current California UST Service Technician certificate issued by the International Code <br /> Council (ICC), and <br /> • A valid, current certificate of training from the manufacturer(s) of the component(s) being tested, <br /> repaired, or serviced, additionally, <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />