Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> UNITED GAS 3440 E MAIN ST, STOCKTON February 02, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 107 CCR 2632(d)(1)(C)Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> The current UST monitoring site plan does not include the piping layout.An accurate UST Monitoring site plan must <br /> be submitted identifying the locations where monitoring will be performed. Immediately log into the California <br /> Environmental Reporting System(CERS)at http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site <br /> Plan. <br /> This is a minor violation. <br /> 113 CCR 2638(d)Failed to submit monitoring system certification test report within 30 days. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on 6/27/2017 <br /> and a test report was submitted on 9/14/17, 2 and a half months late. A copy of the test report must be submitted <br /> within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test reports are <br /> performed in a timely manner. <br /> This is a minor violation. <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change Win 30 days. <br /> A new designated operator(David Turner)was hired on 7/23/2017 and notification was not provided to the EHD <br /> within 30 days of the change. Any changes shall be reported to the EHD within 30 days. Immediately log into the <br /> California Environmental Reporting System(CERS)at http://cers.calepa.ca.gov and upload the notification <br /> identifying all the designated operators for this facility. <br /> This is a minor violation. <br /> 211 CCR 2715(f)(2) Designated operator employee training not performed or log not kept. <br /> The hiring date of the employees was not observed on the training documents performed by the Designated <br /> Operator. The designated operator shall Vain facility employees for which he or she is responsible in the proper <br /> operation and maintenance of the UST system once every 12 months. The training shall include, but is not limited <br /> to: <br /> 1.Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records with the hiring date to the EHD. <br /> This is a minor violation. <br /> FA0006423 PRO231173 SC001 02M212018 <br /> EHD 23-01 Rev.10/31 12 01 7 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />