COMPLIANCE INFO 1985-1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
COMPLIANCE INFO 1985-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 11:30:00 AM
Creation date
11/8/2018 9:41:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-1999
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\COMPLIANCE INFO 1985-1999.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
203
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUI&ANK/LINE/LEAK DETECTOR TEJOREPORT NDE <br /> NDE ENVIRONMENTAL CORPORATION „ <br /> TEST DATE: April 17, 1996 WORK ORDER NUMBER: 965862 <br /> CLIENT ULTRANAR INC SITE: ULTRAMAR 692 <br /> TANK INFORMATION <br /> Tank ID: 87 Bottom to top fill in inches: 122.0 <br /> Product: UNLEADED Bottom to grade fill in inches: 132.0 <br /> Capacity in gallons: 9,929 Fill pipe length in inches: 28.0 <br /> Diameter in inches: 94.00 Fill pipe diameter in inches: 4.0 <br /> Length in inches: 337 <br /> Stage I vapor recovery: coAx <br /> Material: STEEL <br /> Tank: No Stage II vapor recovery: ASSIST <br /> Manifolded Vent: yES <br /> V/R: No <br /> ".. COMMENTS <br /> TANK TEST RESULTS LEAK DETECTOR RESULTS. <br /> Test method: Alert 1000 New/passed Failed/replaced <br /> Psi at tank bottom: 2.05 detector detector <br /> Fluid level in inches: 76.50 <br /> UFT/OFT: UFT Test method: FTA <br /> Fluid volume in gallons: 8,739 Make: RED JACKET <br /> Water level in inches: 0.00 Model: Fx <br /> Test time: 23:19-01:28 S/N: 0322955622 <br /> Number of thermisters: Open time in sec: 3.00 <br /> Specific gravity: 0.745 Holding psi: 13 <br /> Water table depth in inches: 300.00 Resiliency cc: 110 <br /> Determined by(method): MONTR WELL Test leak rate ml/min: 169.0 <br /> Leak rate in gph: -0.003 Metering psi: 10 <br /> RESULT: PASS Calib. leak in gph: 3.00 <br /> RESULT PASS <br /> _COMMENTS COMMEN75S. <br /> ULLAGE TEST RESULTS 'TINE TEST RESULTS <br /> Test method: Alert 1050 <br /> Test time: 02:02-02:12 Material: FIBERGLASS <br /> Ullage volume: 1,190 Diameter(in): 2.0 <br /> Ullage pressure: 1.50 Length (ft): 40.0 <br /> RESULT. PASS Test psi: 50 <br /> Bleedback cc: 100 <br /> DATA FOR UTS-4T ONLY: Test time(min): 30 <br /> Time of test 1: Test 1:start time: 23:33 <br /> finish psi: 50 <br /> Temperature: vol change cc: 10 <br /> Flow rate (cfh): Test 2:start time: 23:43 <br /> Time of test 2: finish psi: so <br /> Temperature: vol change cc: o <br /> Test 3:start time: 23:53 <br /> Flow rate (cfh): finish psi: so <br /> Time of test 3: vol change cc: 0 <br /> Temperature: Final gph: 0.005 <br /> Flow rate (cfh): RESULT: PASS <br /> Test type:AcuRite <br /> COMMENTS. Pump type: PRESSURE Pump make: RED JACKET <br /> '.' COMMENTS <br /> 8906 WALL STREET SUITE 306 AUSTIN TEXAS 78754 512 719-4633 <br />