470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
REMOVAL_2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 2:10:22 PM
Creation date
11/8/2018 9:41:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2006
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\REMOVAL 2006.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 6 of 8 <br />alscience <br />nvironmental Glossary of Terms and Qualifiers <br />aboratories, Inc. <br />Work Order Number: 06-12-0397 <br />Qualifier Definition <br />* See applicable analysis comment. <br />1 Surrogate compound recovery was out of control due to a required sample dilution, <br />therefore, the sample data was reported without further clarification. <br />2 Surrogate compound recovery was out of control due to matrix interference. The <br />associated method blank surrogate spike compound was in control and, therefore, the <br />sample data was reported without further clarification. <br />3 Recovery of the Matrix Spike or Matrix Spike Duplicate compound was out of control due <br />to matrix interference. The associated LCS and/or LCSD was in control and, therefore, <br />the sample data was reported without further clarification. <br />4 The MS/MSD RPD was out of control due to matrix interference. The LCS/LCSD RPD <br />was in control and, therefore, the sample data was reported without further clarification. <br />5 The PDS/PDSD associated with this batch of samples was out of control due to a matrix <br />interference effect. The associated batch LCS/LCSD was in control and, hence, the <br />associated sample data was reported with no further corrective action required. <br />A Result is the average of all dilutions, as defined by the method. <br />B Analyte was present in the associated method blank. <br />C Analyte presence was not confirmed on primary column. <br />E Concentration exceeds the calibration range. <br />H Sample received and/or analyzed past the recommended holding time. <br />J Analyte was detected at a concentration below the reporting limit and above the <br />laboratory method detection limit. Reported value is estimated. <br />N Nontarget Analyte. <br />ND Parameter not detected at the indicated reporting limit. <br />Q Spike recovery and RPD control limits do not apply resulting from the parameter <br />concentration in the sample exceeding the spike concentration by a factor of four or <br />greater. <br />U Undetected at the laboratory method detection limit. <br />X % Recovery and/or RPD out -of -range. <br />Z Analyte presence was not confirmed by second column or GC/MS analysis. <br />7440 Lincoln Way, Garden Grove, CA 92841-1427 • TEL:(714) 895-5494 • FAX: (714) 894-7501 <br />
The URL can be used to link to this page
Your browser does not support the video tag.