My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1916
>
2300 - Underground Storage Tank Program
>
PR0527728
>
COMPLIANCE INFO 2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 1:27:18 PM
Creation date
11/8/2018 9:43:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0527728
PE
2351
FACILITY_ID
FA0018792
FACILITY_NAME
MARCH AND BIANCHI CHEVRON
STREET_NUMBER
1916
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09603029
CURRENT_STATUS
01
SITE_LOCATION
1916 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1916\PR0527728\COMPLIANCE INFO 2009 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
9/28/2017 8:32:42 PM
QuestysRecordID
3652760
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification Form: iendum for Vacuum/pressure Interstitial S"rs • � �j gj� <br /> I. Results of Vacuum/Pressure Monitoring Equipment Testing CEC 3 12015 <br /> This page should be used to document testing and servicing of vacuum and pressure interstitia1' WROWEWP,1 <br /> form must be included with the Monitoring System Certification Form, which must be provid ;Ii tusygFdttL <br /> owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the local <br /> agency regulating UST systems within 30 days of test date. <br /> Manufacturer:VEEDER ROOT Model: System Type: Pressure;Vacuum <br /> Sensor fD <br /> Compone 87 PRODUCT LINE <br /> S1 <br /> Sensor Functionality Test Result: X Pass; Fail Interstitial Communication Test Result: Pas <br /> Compone ALL VENTS/VAPOR <br /> S2 <br /> Sensor Functionality Test Result: X Pass; Fail Interstitial Communication Test Result:Pass <br /> Compone 87TANKANNULAR <br /> S 3 Sensor Functionality Test Result: X Pass; Fail Interstitial Communication Test Result:Pass <br /> Compone 91 PRODUCT LINE <br /> S4 Sensor Functionality Test Result: X Pass; Fail Interstitial Communication Test Result:Pass <br /> Compone DIESEU91 TANKANNULAR <br /> S6 Sensor Functionality Test Result: X Pass; Fail Interstitial Communication Test Result:Pass <br /> Compone DIESEL PRODUCT LINE <br /> S6 Sensor Functionality Test Result: X Pass; Fail Interstitial Communication Test Result:Pass <br /> Compone <br /> Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: <br /> Compone <br /> Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: <br /> Compone <br /> Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: <br /> Compone <br /> Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: <br /> How was interstitial communication verified? <br /> Leak Introduced at Far End of Interstitial Space;' Gauge; Visual Inspection; Other(Describe in Sec.J, below) <br /> Vacuum was restored to operating levels in all interstitial spaces: Yes No(Lf no, describe in Sec.J, below) <br /> J. Comments: <br /> Page_of_ <br /> If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br />
The URL can be used to link to this page
Your browser does not support the video tag.