COMPLIANCE INFO 2003 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
COMPLIANCE INFO 2003 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:07 PM
Creation date
11/8/2018 9:43:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2007
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
TESORO (MOBIL) 68222
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2132\PR0231669\COMPLIANCE INFO\COMPLIANCE INFO 2003 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2007
QuestysRecordDate
6/24/2016 3:46:18 PM
QuestysRecordID
3117371
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUL-05-2007 03:40 Service Station Systems 408 938 8888 P.O2 <br />Monitorik.„,; System Equipment _"ertification <br />For Use By All Jurisdictions Within The State of California <br />Authority Cited- Chapter 6 7, Health and Safety Code; Chapter /6, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment A separate certification or report must b� <br />,re aced for elicit monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br />to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br />within 30 days of test date. <br />A. General Information <br />Facility Name: USA 68222 Bldg. No.: <br />Site Address: 2132 Mariposa Rd. @ Farmington Rd. City: Stockton, CA Zip: 95205 - <br />Facility Contact Person: Manager Contact Phone No.: (209) 946-9282 <br />Make/Model of Monitoring System: Gil EMC Date of Testing/Servicing: 614/07 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Tank ID: 01-Regu <br />Tank ][D• 02 -Plus <br />(g In - Tank Gauging Probe. <br />Model: <br />VKU7345-107 <br />pI In - Tank Gauging Probc. <br />Model; <br />VR ea7390.107 <br />M Annular Space or Vault Sensor. <br />Model: <br />Ronan 1.91-3 _ <br />3 Annular Space or Vault Sensor. <br />Model: <br />Ramn tss <br />0 Piping Sump \ Trench Sensor (s). <br />Model: <br />VR 7843ao.ma <br />IX Piping Sump \ Trench Sensor (s). <br />Model: <br />VR 7943110.2011 <br />m Fill Sump Sensor (s). <br />Model: <br />_ <br />VR 724389.2011 <br />(X Fill Sump Sensor (s). <br />Model <br />VR 794390-209 <br />11 Mechanical Line Leak Detector. <br />Model: <br />list i I"S74 <br />(x Mechanical Line Leak Detector. <br />Model: <br />1C)1111Y67S <br />❑ Electronic Linc Leak Detector. <br />Model: <br />Nene --[3 <br />Electronic Line Leak Detector. <br />Model: <br />Nag. <br />13Tank Overfill \ High -Level Sensor. <br />Model: <br />Na.a, <br />p Tank Overfill \ High -Level Sensor. <br />Model: <br />Nww <br />❑ Other ( specify equipment type and model in Section E on Page 2). <br />❑ Other ( specify equipment type and model in Section E on Page 2). <br />Tank ID•a3-Prem <br />Tank ID: 04-DieselIX <br />In - Tank Gauging Probe. <br />Model: <br />VR 847399.107 <br />13 In - Tank Gauging Probe. <br />Model; <br />VR6473 107 <br />Is Annular Space or Vault Sensor. <br />Mode]: <br />R.mn t <br />rXas� Annular Space or Vault Sensor. <br />Model;Ragan <br />1.5.5[XPiping <br />Sump \ Trench Sensor (s). <br />Model: <br />vR 79438* -208 <br />G9 Piping Sump \ Trench Sensor (s). <br />ModcL <br />vR7a3ee.2aIg <br />Fill Sump Sensor (s). <br />Model: <br />VR794380-208 <br />IL <br />3 Fill Sump Sensor (s). <br />Model: <br />VR 7943MNBQ <br />Mechanical Line Leak Detector <br />Model: <br />R31194s7-s <br />Qt Mechanical Line Leak Detector. <br />Model: <br />Rd 118.067.8 <br />(3Electronic Line Leak Detector. <br />Model: <br />Nene <br />Q Electronic Line Leak Detector. <br />Model: <br />None <br />(3Tank Overfill \ High -Level Sensor. <br />Model: <br />None <br />E] Tank Ovcrtill \ High -Levi l Sensor. <br />Model: <br />Nona <br />[3 Diner ( specify equipment type and model in Section E on Page 2). <br />r3 other ( specify equipntmt type and mmlel in Section E on Page 2). <br />Dispenser 1D• 01-02 <br />_ <br />Dispenser 04-05 <br />CK Dispenser Containment Sensor (s). <br />Model: <br />VR 70011 m _ <br />RI Dispense Containment Sensor (s). <br />Model: <br />VR 7943/10308 <br />13 Shear Valve (s). <br />IN Shear Valve (s). <br />E3 Dispenser Containment Float (s) and <br />Chain (s). <br />❑ Dispenser Containment Float (s) and Chain (s). <br />Dispenser ID: 05- <br />_ <br />Dispenser l.- 07.08 <br />IN Dispenser Containment Sensor (s). <br />Model. <br />yR7114390-208 _ <br />❑ Dispenser Containment Sensor (s). <br />Model: <br />VR 79439030/1 <br />Shear Valve (s). <br />Cl Sheat Valve (s). <br />❑ Dispenser Containment Float (s) mid Chain (s). <br />❑ Dispenser Containment Float (s) and Chain (s). <br />Dispenser ID. 09-10 <br />Dispenser ID• 11- <br />❑ Dispenser Comainmcnt SCn9*r (3). <br />Model: <br />VR 794390-208 <br />❑ Dispenser Containment Sensor (s). <br />Model: <br />V1179,13110-208 <br />❑ Shear Valve (s). <br />❑ Shear Valve (s). <br />❑ Dispenser Containment Float (s) and Chain (s). <br />❑ Dispenser Containment Float (s) and Chain (s). <br />'If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturer's guidelines. Attached to this Certification is information (e.g. manufactures' checklists) necessary to verifv that this <br />information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, I have also attached a copy of the; (check all that apply): IE System set-up M Alarm history report <br />Technician Name (print): Randy A Wilkerson Signature: /U19L_. <br />Mfg. Cert.#.: <br />A32404 <br />ICC# 5258560 -UT License. No.: 485184 <br />Testing Company Name Serv. Sta. Sys. Phone No.: (408) 971-2445 <br />Site Address: 2132 Mariposa Rd. _ Farmington Rd. Date of Testing/Servicing: 614/07 <br />