My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2003 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
COMPLIANCE INFO 2003 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:07 PM
Creation date
11/8/2018 9:43:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2007
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
TESORO (MOBIL) 68222
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2132\PR0231669\COMPLIANCE INFO\COMPLIANCE INFO 2003 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2007
QuestysRecordDate
6/24/2016 3:46:18 PM
QuestysRecordID
3117371
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N toring System Certification <br />J <br />Site Address: 2132 MARIPOSA ROAD Date of Testing/Service: 06/08/2006 <br />D. Results of Testing/Servicing <br />Software Version Installed: <br />Complete the following checklist: <br />rX-1 Yes <br />El No ` <br />Is the audible alarm operational? <br />Q Yes <br />❑ No ` <br />Is the visual alarm operational? <br />Q YesNo <br />` <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />nx Yes <br />❑ No' <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not <br />interfere with their proper operation? <br />Yes <br />No' <br />M N/A <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />Yes <br />❑ No ` <br />❑ N/A <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive <br />shut -down? (check all that apply) ❑x Sump/Trench Sensors; ❑x Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ❑ Yes Ej No <br />❑x Yes <br />❑ No - <br />N/A <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (Le.: no mechanical <br />overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill points(s) and operating <br />properly? If so, at what percent of tank capacity does the alarm trigger? eo <br />❑ Yes` <br />ONO <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />manufacturer name and model for all replacement parts in Section E, below. <br />❑x Yes* <br />❑ No <br />Was liquid found inside any secondary containment systems designed as dry systems? (check all that apply) ❑ Product; <br />El Water. If yes, describe causes in Section E, below. <br />❑x Yes <br />ONO' <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if applicable. <br />❑X Yes <br />❑ No ` <br />Is all monitoring equipment operational per manufacturers' specifications? <br />' In Section E below, describe how and when these deficiences were or will be corrected. <br />E. Comments: <br />WATER IN DIESEL FILL SUMP, ABOUT 10 -GALLONS OF WATER WAS PUMP OUT AND DISPOSED OF IN HAZARDOUS WASTE <br />DRUM. SUMP WAS DRY AND SENSOR WAS SET BACK DOWN TO LOWEST POINT. <br />Page 2 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page