Laserfiche WebLink
1%.i San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sigov.org/eh <br /> Underground Storage Tank Program Inspection Repo : <br /> Facility Address: Date: <br /> Facility Name: 2132 MARIPOSA RD STOCKTON Aril 26 2016 <br /> TESORO MOBIL 68222 <br /> ST System Observations <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump _ ❑V ❑R ❑COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed ❑V ❑R ❑COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ■V ❑R ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty ❑V ❑R ❑COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ❑V ❑R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V ❑R ❑COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden ❑V ❑R ❑COS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V ❑R ❑COS <br /> 329 CCR 2717.1(g) <br /> Tampered with red tag ❑V ❑R ❑COS <br /> 330 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R o COS <br /> 331 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 332 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> they Viotatio" <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation in V ❑R ❑COS <br /> MUM OF VIOLATIONS <br /> (CLASS.I,CLASS II,or MINOR-Notice to Comply)F= <br /> Item# Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. Included in the packet with the Letter from <br /> Chief Financial Officer, is a section titled"Guarantee"that is dated March 23, 2015. Current financial responsibility <br /> documents are required to be submitted annually. Immediately log into the California Environmental Reporting System <br /> (CERS) at http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a minor violation. <br /> Page 3 of 5 <br />