Laserfiche WebLink
San Joaquin County AMENDED <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sjoov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TESORO MOBIL 68222 2132 MARIPOSA RD STOCKTON Aril 26 2016 <br /> UST System Observations <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump 771 <br /> V ❑R ❑COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed ❑V ❑R ❑COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ■V ❑R ■COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty c V ❑R ❑COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ❑V ❑R o COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V ❑R u COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden ❑V ❑R ❑COS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V ❑R u COS <br /> 329 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 330 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 331 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms in V ❑R o COS <br /> 332 CCR 2631.1 UST system not compatible with the substance stored ❑V n R ❑COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R c COS <br /> 'Pressurized Pt <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V I R COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> Other Violation`s' <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation u V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> 1,CLASS II,or MINOR-Notice to Comply):, <br /> Item # Remarks <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plan for TA0507192 needs to have <br /> the mechanical line leak detector model changed from FX1V to LD2000; the monitoring plan for TA0507193 needs to <br /> have the mechanical line leak detector model changed from FX1 V to FX2V. Under RECORDKEEPING for all four <br /> tank monitoring plans, change"No"to"Yes'for Visual Inspection Records. The monitoring plan must be uploaded to <br /> the California Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, <br /> and submit for review by the EHD. <br /> This is a minor violation. <br /> Page 3 of 5 <br />