Laserfiche WebLink
Monitoring System Equipment Certirication MAY 2 5 2016 <br /> For Use By All Jurisdictions Within The State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23, California Code ofpeo�,�,4payINW� w e <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or re> f <br /> mgpared for each monitoring system control panel by the technician who performs the work A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name:Mobil/Tesoro Bldg.No.: <br /> Site Address: 2132 Mariposa Rd. City: Stockton, CA Gip: 95205 <br /> Facility Contact Person: Manager Contact Phone No.: (209)467-3918 <br /> Make/Model of Monitoring System: VR TLS-350 Date of Testing/Servicing: 4/26116 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicate specific equipment inspected/serviced: <br /> Tank ID:01-Regu Tank ID: 02-Plus <br /> ® In-Tank Gauging Probe, Model: VR 947390-107 0 In-Tank Gauging Probe. Model: VR a4A961M <br /> 0 Annu ur Space or Vault Sensor. Model: Ronan L 3 ® Annular Space or Vault Sensor. Model: VR 711i&3f 20 <br /> ® Piping Sump\Trench Sensor(s). Model: VR 7sue0-20e ® Piping Sump\Trench Sensor(s). Model: VR 7euw2011 <br /> ® Fill Sump Sensor(s). Model: VR794380-208 ® Fill Sump Sensor(a). Model: VR 7WIHNNIs <br /> ® Mechanical Line Leak Detector. Model: Vleadara LD2000 ® Mechanical Line Leak Detector. Model: R 1104)074 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> a Tank Overfill\Ifigh-Level Sensor. Model: VR 790091-001 ® Tank Overfill\High-Level Sensor. Model M71100914)01 <br /> ❑ Other(specify equipment type and model in Section F,on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: 03-Prem Tank ID: 04-Diesel <br /> 0 In-Tank Gauging Probe. Model: VR x7390-107 ® In-Tank Gauging Probe. Model: VR U739&107 <br /> ® Annular Spa"or Vault Sensor. Model: Ronan LS-3 ® Annular Space car Vault Sensor. Model: Ronan Lsa <br /> l9 Piping Sump\Trench Sensor(a). Model: VR 794380.200 ® Piping Sump\Trench Sensor(s). Model: yR 794380.208 <br /> ® Fill Sump Sensor(s). Model: VR 794390.208 ® Fill Sump Sensor(a). Model: VR 794380.28 <br /> ® Mechanical Line Leak Detector. Model: RJ 110-050.5 ® Mechanical Line Leak Detector. Model: vauerlau WEN <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ® Tank Overfill\High-Level Scum. Model VR 790091401 ® Tank Overfill\High-Level Sensor. Model: VR n00914)01 <br /> ❑ Other(specify equipment type and model in Section F on Pago 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 01.02 Dispenser ID: (13-04 <br /> ® Dispenser Containment Sensor(a). Model: VR 794380.208 ® Dispenser Containment Sensor(s). Model: VR 794380-278 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(a). ❑ Dispenser Containment Float(s)and Chain(a). <br /> Dispenser ID: 05-06 Dispenser ID: 07-08 <br /> ® Dispenser Containment Sensor(s). Model VR 79,1390-208 ® Dispenser Containment goDsof(S). Model: VR 7UMB-208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(a)and Chain(s). <br /> Dispenser ID: 0840 Dispenser ID: 11.12 <br /> ® Dispenser Containment Sensor(s). Model: VR na4380-208 10 Dispeaser Containment Sensm(s). Model: VR 7943110a08 <br /> ® Shear Valve(s). C Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 4f the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility <br /> C.Certification- 1 certify that the equipment Identified in this document was inspected/serviced in accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e.g.manufactures'checklists)necessary to verify that this <br /> Information is correct and is Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> repotEa,f have also attached a copy of the; (cheekdl thatapply): ❑ Systemset-up ❑ Alarm history report <br /> Technician Name(print): Kris Bell Signature:: <br /> Mfg.Cert.#.: B33709 ICC# 5297793-UT License.No.: 485184 <br /> Testing Company Name: Service Station Systems PhoneNo.: (408)971-2445 <br /> Testing Company Address: 680 Quinn Ave., San Jose,CA 95112 Date of Testing/Servicing: 4/26116 <br />