My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
COMPLIANCE INFO 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/8/2018 9:44:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
TESORO (MOBIL) 68222
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2132\PR0231669\COMPLIANCE INFO\COMPLIANCE INFO 2016.PDF
QuestysFileName
COMPLIANCE INFO 2016
QuestysRecordDate
6/15/2017 6:48:05 PM
QuestysRecordID
3131588
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> i <br /> Monitoring System Certification-Page 2.of 3 <br /> Site Address: 2132 Mariposa Rd. Date of Testing/ig�CL pery�i UI <br /> D. Results of Testing/Servicing lglr®r. <br /> Software Version Installed. 333.05 MAY 2 5 2016 <br /> Com tete the following checklist: <br /> Il Yes 0 No* Is the audible alarm operational? 7equipment <br /> 0 Yes 0 No* Is the visual alarm operational? <br /> ® Yes 0 No* Were all sensors visual) inspected,functional) tested,and confirmed operational? <br /> ® Yes 0 No* Were all sensors installed at lowest point of secondary containment and positioned sonot interfere with their proper operation? <br /> 0 Yes 0 No* If alarms are relayed to a remote monitoring station,is all communications equipmen <br /> 0 N/A operational? <br /> a Yes 0 No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> 0 N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) 0 Sump/Trench Sensors; ® Dispenser Containment Sensors. <br /> Did you confine positive shut-down due to leaks and sensor failure/disconnection? ® Yes ❑ No <br /> 8 Yes 0 No* For tank systems that utilize'the monitoring system as the primary tank overfill warning device(i.e.no <br /> 0 N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? 90 % <br /> ® Yes* 0 No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> a Yes* 0 No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> 0 Product;® Water. If yes,describe causes in Section E,below. <br /> 0 Yes 0 No* Was monitorirLsysterrjset-up reviewed to ensure proper settings? Attach set-up reports, i a licable. <br /> 0 Yes 1 0 ATo* I Is all monitor;•_g equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Replaced Battery on TLS.for PM purposes. <br /> E-stops tested & Passed <br /> Replaced Plus STP Sump Sensor(794380-208)Tested & Passed. <br /> Removed apprx. 12oz of water from 87, 89 and 91 Fill Sumps. <br />
The URL can be used to link to this page
Your browser does not support the video tag.