My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2467
>
2300 - Underground Storage Tank Program
>
PR0231818
>
COMPLIANCE INFO 2002 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:06 PM
Creation date
11/8/2018 9:44:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2013
RECORD_ID
PR0231818
PE
2361
FACILITY_ID
FA0022456
FACILITY_NAME
Foodliner, Inc.
STREET_NUMBER
2467
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
Rd
City
Stockton
Zip
95205
APN
17130003
CURRENT_STATUS
02
SITE_LOCATION
2467 E Mariposa Rd
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2467\PR0231818\COMPLIANCE INFO 2002 - 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
+ MONfoo6RING SYSTEM CERTIFIwiOTION <br /> For Use By AH Jnrdsdiclions I17117in Me Slide o/'Calybrnin D <br /> + Aadioriq,Cited:C'hapler 6.7, Health and Si+f r),Code; Chopler 16, Division 3, Tille 13, Cellifornia('ode aJ'Re/gtuln � <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certific on oi" must be <br /> prepared for each monitorine system control oanel by the technician who performs the work. A copy of thisTOr be prvU <br /> the tank system owner/operator. The owner/operator n11W sublliit a copy of this form to the local agency to systei{is <br /> within 30 days of test date. �r7 <br /> A. General Information /TjSFh'!//C�S�TFj <br /> Facility Name: ��I,ILILI Bldg.No.: <br /> Site Address: Z413 �. Alo/%osA 4a City: 5 o To Zi <br /> Facility Contact Person: �DA ✓/DI Contact Phone No.: ( >O`f ) !2&, <br /> Make/Model of Monitoring System: XtL,.�xJ o0 1 Date of Testing/Servicing: <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate 99ecific a ui ment inspected/serviced: <br /> Tank ID: D/AE Tank ID: <br /> 25 In-Tank Gauging Probe. Model: Mph O In-Tank Gauging Probe. Model: c <br /> &Annular Space or Vault Sensor. Model: k LS ❑ Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: to ws ❑ Piping Sump i Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: Q Fill Sump Sensor(s). Model: <br /> 2( Mechanical Line Leak Detector. Model: STP-MLD• h ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> L3 Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment t e and model in Section E on Page 2). ❑ Other(specify equipment t e and model in Section E on Pae 2). <br /> Tank ID: D I E 3 Tank ID: <br /> 1.4., In-Tank Gauging Probe. Model: MAoa ❑ In-Tank Gauging Probe. Model: <br /> pt Annular Space or Vault Sensor. Model: IA4,% ❑ Annular Space or Vault Sensor. Model: <br /> �1 Piping Sump/Trench Sensor(s). Model: LA" Q Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> JL Mechanical Line Leak Detector. Model:dVir-Mut -b ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment[ e and model in Section E on Page 2). ❑ Other(specify equipment a and model inWonft2e2). <br /> Dispenser ID: / 'Y Z Dispenser ID; <br /> * Dispenser Containment Sensor(s). Model: IArb ❑ Dispenser Containment Sensor(s). Model: <br /> R Shear Valve(s). 13 Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: ate{yDispenser ID: <br /> fz <br /> A Dispenser Containment Sensor(s). Model: Ltt+S ❑ Dispenser Containment Sensor(s). Model: <br /> li Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dis enser Containment Float(s)and Chain(s). I O Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: I Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model' A ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). Q Shear Valve(s). <br /> UDispenser Containment Float(s)and Clnain(s). ❑ Dibrenser Containment Float(s)and Chain(s). <br /> -If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the fac• ty. <br /> C. Certification - 1 certify that the equipment identified in this document wits inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Phan showing the layout of monitoring equipment. For any equipment capable of generating Stich <br /> reports,l have also attached it copy of the report;fc6eck all that apply): lkSyat7 _ A Alarm history report <br /> Technician Name(print): 7-4pie ;�.i, o Signature:J <br /> Certification No.: ��zve zw 33a 7 —UT <br /> zh?.3 License. 1)7r, ## W ./&.2b <br /> Testing Company Name: AEOCOA _ TeSr Phone No.: Aa2 ) _-Vt1 - p/",p, <br /> Site Address: ZYS l ri_ I-11AlL/P65s - Date of Testing/Servicing: I- <br /> Page 1 of 3 03/01 <br /> Monitoring System Certification <br /> R. Results of Testing/Servicing <br />
The URL can be used to link to this page
Your browser does not support the video tag.