My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2467
>
2300 - Underground Storage Tank Program
>
PR0231818
>
COMPLIANCE INFO 2002 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:06 PM
Creation date
11/8/2018 9:44:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2013
RECORD_ID
PR0231818
PE
2361
FACILITY_ID
FA0022456
FACILITY_NAME
Foodliner, Inc.
STREET_NUMBER
2467
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
Rd
City
Stockton
Zip
95205
APN
17130003
CURRENT_STATUS
02
SITE_LOCATION
2467 E Mariposa Rd
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2467\PR0231818\COMPLIANCE INFO 2002 - 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e" Appendix VI RECE V ED <br /> JUN 1 4 1010 <br /> MONITORING SYSTEM CERTIFICATION ENVIRONMENT HEALTH <br /> For Use By All Jurisdictions Within the State of California PERMIT/SERVICES <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility <br /> Name: BBJ TRUCKING Bldg.No.: <br /> Site <br /> Address: 2431 EAST MARIPOSA ROAD City: STOCKTON Zip: 95205 <br /> Facility Contact <br /> Person: Contact Phone No.: (209)941-2576 <br /> MaketModel of Monitoring System: INCON 1001 Date of Testing/Servicing: 05-26-10 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicates ectfic a ui ment ins ectecilserviced: <br /> Tank ID: NORTH DIESEL Tank ID: SOUTH DIESEL <br /> E In-Tank Gauging Probe. Model: MAG E In-Tank Gauging Probe. Model: MAG <br /> E Annular Space or Vault Sensor. Model: ULS E Annular Space or Vault Sensor, Model! ULS <br /> E Piping Sump/Trench Sensor(s). Madel: ULS E Piping Sump/Trench Sensor(s). Model: ULS <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> E Mechanical Line Leak Detector. Model: STP MLD E Mechanical Line Leak Detector. Model: STP MLD <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Motlel: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> TanklD: TanklD: <br /> ❑ In-Tank Gauging Probe. Model ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space of Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Madel: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model. ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 34 <br /> E Dispenser Containment Sensor(s). Model: ULS E Dispenser Containment Sensor(s). Model: ULS <br /> E Shear Velvets). E Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). __ J <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensoria). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chaints). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment Identified in this document was Inspected/serviced In accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ❑System set-up I]Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: <br /> Certification No.: 5273934-UT __ License No: 08-1740 <br /> Testing Company Name: AFFORDA-TEST ____ Phone No. (209)744-0113 _ - <br /> TesOng Company Address: 418 2 STREET GALT,CA 95632 Date of Testing/Servicing: 05-26-10 -- <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br /> �c C -t1 <br />