Laserfiche WebLink
CA-039 <br /> Tank 1 <br /> - STATE OF CALIFORMA <br /> STATE WATER RESOURCES CONTROL BOARD iy '- <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. ' n s <br /> 14 <br /> MARK ONLY ® I NEW PERMIT Q 3 RENEWAL PERMIT O 5 CHANGE OF INFORMATION ❑ 7 R NTLY CLOSED ONSITE <br /> ONE ITEM O 2 INTERIM PERMIT O 4 AMENDED PERMIT ❑ 8 TEMPORARY TANK CLOSURE O 9 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: Stockton, CA <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.• DD 1 B. MANUFACTURED BY: Modern Welding <br /> C. DATE INSTALLED(MO/DAYNEAR) 9/15/95 D. TANK CAPACITY IN GALLONS: 20,000 <br /> II.TAN KCONT ENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> A O 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. ❑ 1aUNLEADED DIESEL <br /> ❑ 8 METHANOL AVIATION GAS <br /> ❑ 2 PETROLEUM ❑ BO EMPTY ❑ 1 PRODUCT O 1DUNLEADED ❑ 5 JET FUEL ❑ ] METHANOL <br /> O 3 CHEMICALPRODUCT ❑ 95 UNKNOWN O 2 WASTE O 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.0: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.8.AND C,AND ALL THAT APPLIES IN BOX D AND <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER O 95 UNKNOWN <br /> SYSTEM ® 2 SINGLE WALL a 4 SECONDARY CONTAINMENT (VAULTED TAN19 ❑ M OTHER <br /> B. TANK ❑ 1 BARE STEEL O 2 STAINLESS STEEL ❑ 3 FIBERGLASS 4 STEELCLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL F-] 5 CONCRETE ❑ e POLYVINYL CHLORIDE ❑ ] ALUMINUM a 8 100% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTank( ❑ B BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR O 5 GLASS LINING ® 8 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ® 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE O95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) S OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) 9 <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A&> PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A&2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U_ 5 ALUMINUM A U B CONCRETE A U 7 STEEL W/COATING A U B IDD% METHANOL COMPA�%TIBLE W/FRP <br /> PROTECTION A, GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A(U)00 OTHER ENg/Q-r-1 <br /> �—� <br /> D. LEAK DETECTION [ ' AUTOMATIC LINE LEAK DETECTOR F] 2 LINE TGHTNESS TESTING MONROIIING ❑ W OTHER( <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING CRr4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ 8 TANK TESTING 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ M OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO❑ <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANPSNAMEMarc en PATEC� <br /> RINTEDa SWNATUREI V.P. Snvir. Serv. <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY 9 JURISDICTION 9 FACILITY 9 TANK 9 <br /> STATE I.D.# <br /> PERMITNUMBER PERMITAROVED V TE PERMIT EXPIRATIONDATE <br /> P <br /> 9119 <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. yJ( <br /> FILE THIS FORM WITH THF I OCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FORM B (1291) ` ^ FOROa%BRE <br /> 3 <br /> 3 '� 0 g-�a- Y8 0 of (HJ <br />