My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MINER
>
1950
>
2300 - Underground Storage Tank Program
>
PR0504240
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2019 9:25:04 AM
Creation date
11/8/2018 9:45:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0504240
PE
2361
FACILITY_ID
FA0006136
FACILITY_NAME
QUICK TRUCK REPAIR
STREET_NUMBER
1950
Direction
E
STREET_NAME
MINER
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
15308006
CURRENT_STATUS
02
SITE_LOCATION
1950 E MINER AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MINER\1950\PR0504240\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
8/17/2016 3:41:51 PM
QuestysRecordID
3168581
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
neo ^ e <br /> r-: <br /> STATE OF CALIFORNIA c°'. <br /> STATE WATER RESOURCES CONTROL BOARD i� ,�; »o <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B y� 3 0 <br /> ..ACOMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. �"°"� <br /> MARK ONLY ❑ i NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED D <br /> DBAOR FACILITY NAME WHERE TANK IS INSTALLED: 050 f, MillZAJ A JCI <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN � V <br /> A. OWNER'S TANK I.D.• B. MANUFACTURED BY: ft <br /> C. DATE INSTALLED(MO/DAYNE R) 01- D. TANK CAPACITY IN GALLON!". <br /> ILTANKCONTENTS IFA-11S MARKED.COMPLETE ITEM C. <br /> A. 1 MOTOR VEHICLE FUEL O 4 OIL B. C la REGULAR O 3 DIESEL O 6 AVIATION GAS�1 �I UNLEADED o 4 GASAHOL <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY F< PRODUCT ❑ 1bUNLMIDM ❑ 5 JETFUEL ❑ 7 METHANOL <br /> ❑ 3 CHEMICALPRODUCT 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.# <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND <br /> A. TYPE OFI)p 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ^❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS 4 STEELCLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL O 5 CONCRETE O 6 POLYVINYL CHLORIDE O 7 ALUMINUM 08 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING F;;Qe6 UNLINED O 95 UNKNOWN O 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE/WITH 10 METHANOL? YES NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE O95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) I OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDORU IF UNDERGROUND,BOTH IF APPLICA13LE <br /> A. SYSTEM TYPE A U 1 SUCTION p PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL At 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN p 99 OTHER <br /> D. LEAK DETECTION Xl AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 31 <br /> MONITORING E] 99 OTHER <br /> V.TANK LEAK DETECTION <br /> F � 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING [-] 4 AUTOMATIC TANK GAUGING ❑ 5 G <br /> ._ ROUND WATER MONITORING <br /> 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN 99 1 <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED E ST USED(MO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> (PRINTED a SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.# ja = � 1,516151-711711 <br /> ,5 n�� <br /> PERMIT NUMBER PERM IT APPROVED BYIDATE PERMIT EXPIRATION DATDATELL-��-.L-I-�J <br /> FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FOR'MT A HAS BEEN LFILED. <br /> -13- /aJ F0R0WIbR5 <br /> A� <br />
The URL can be used to link to this page
Your browser does not support the video tag.