Laserfiche WebLink
AOL <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sjaov.orc/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RALEYS FUEL STATION M56 4219 E MORADA LN, STOCKTON July 20, 2017 <br /> UST System Observations <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status V R ,COS <br /> 324 CCR 2717.1(g) Tamperedwith red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(1) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 330 1 CCR 2631 Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> 401 CCR 26361 Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(preJan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) n V ❑.R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation o V _i R i COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V n R 7 COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator at the time of inspection, July 20, 2017. The EHD <br /> will generate and provide a complete report to the facility operator. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> Note: Communication in under dispenser containment 5-6 was verified by a port located near the brine <br /> reservoir. Communication needs to be tested away from the brine reservoir. Immediately contact a properly <br /> licensed, trained, and certified contractor to install the necessary component at the far end of the under <br /> dispenser containment 5-6, away from the reservoir. <br /> Note: A boot in the 87-product submersible turbine pump sump and a boot in the 91-product fill sump were <br /> broken. Immediately contact a properly licensed, trained, and certified contractor to repair/replace the broken <br /> boots under permit and inspection by the EHD. <br /> FA0016523 PR0524617 SCO01 07/20/2017 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 4 Underground Storage Tank Program OR <br />