My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORADA
>
4219
>
2300 - Underground Storage Tank Program
>
PR0524617
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2019 2:08:44 PM
Creation date
11/8/2018 9:46:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0524617
PE
2351
FACILITY_ID
FA0016523
FACILITY_NAME
AISLE 1 #2356
STREET_NUMBER
4219
Direction
E
STREET_NAME
MORADA
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12429017
CURRENT_STATUS
01
SITE_LOCATION
4219 E MORADA LN
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MORADA\4219\PR0524617\COMPLIANCE INFO 2017 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2017 - PRESENT
QuestysRecordDate
6/5/2018 9:28:19 PM
QuestysRecordID
3909979
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
300
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sogov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RALEYS FUEL STATION #>i356 4219 E MORADA LN STOCKTON Jul 10 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plans are not current and/or not approved by the EHD. The plans list both a TLS 350 and a TLS 350R <br /> for the monitoring panel on site. The panel observed is a TLS 350R. The monitoring plans must be uploaded to the <br /> California Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and <br /> submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br /> The 87 STP sump chase pipe boot and the 91 fill sump chase pipe boot were replaced on 8/14/17 and a permit was <br /> not obtained from the EHD. Emergency repairs relating to UST system monitoring and release detection may be <br /> performed by a properly licensed, trained, and certified contractor pursuant to the EHD'S policy and a permit obtained <br /> within one business day from the EHD. All other repairs must have a permit submitted to and approved by the EHD <br /> prior to beginning work. Immediately obtain a permit from the EHD for this work. A"Failure to Obtain a Permit" <br /> penalty applies. *A permit application was submitted on June 4, 2018, but has not yet been completed. <br /> This is a repeat violation, Class II. <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the UDC. The <br /> underground storage tank system shall be operated to prevent unauthorized releases. Immediately provide approved <br /> secondary containment for the filters under permit and inspection by the EHD. <br /> This is a Class II violation. <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> Boots on the chase piping in the diesel STP sump, diesel fill sump, 91 STP sump, and 87 fill sump were observed <br /> broken, exposing the ends of the open piping. No vacuum sensors were monitoring the secondary chase piping. The <br /> interstitial space of the UST shall be maintained, as designed, under constant vacuum such that a breach in the <br /> primary or secondary containment is detected before the hazardous substance is released into the environment. <br /> Correct immediately by having a properly licensed, trained, and certified contractor replace the failed component with a <br /> functional component(LG 113-x listed, if applicable) and obtain a permit within one business day from the EHD. If the <br /> failed component can't be replaced immediately, there is a possibility that the 87, 91, and diesel UST systems may <br /> be red tagged to prevent fuel inputs. <br /> This is a Class II violation. <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the UDC. Secondary <br /> containment shall be provided for all single-walled UST components. Immediately provide approved secondary <br /> containment for the filters under permit and inspection by the EHD. <br /> This is a Class II violation. <br /> FA0016523 PR0524617 SCO01 07/10/2018 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.