Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORADA
>
4219
>
2300 - Underground Storage Tank Program
>
PR0524617
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2019 2:08:44 PM
Creation date
11/8/2018 9:46:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0524617
PE
2351
FACILITY_ID
FA0016523
FACILITY_NAME
AISLE 1 #2356
STREET_NUMBER
4219
Direction
E
STREET_NAME
MORADA
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12429017
CURRENT_STATUS
01
SITE_LOCATION
4219 E MORADA LN
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MORADA\4219\PR0524617\COMPLIANCE INFO 2017 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2017 - PRESENT
QuestysRecordDate
6/5/2018 9:28:19 PM
QuestysRecordID
3909979
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
300
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Stacy Rivera [EH] <br /> From: Marty Weithman <martyw@servicestationsystems.com> <br /> Sent: Thursday, August 2, 2018 3:49 PM <br /> To: Stacy Rivera [EH]; Elena K. Manzo [EH] <br /> Cc: Mike Gabbert; Ryan Brownlee-Able <br /> Subject: Raleys, 4219 Morada Ln, Stockton; Updated Scope of work and Cut sheets <br /> Attachments: SKM_C55818080214430.pdf <br /> Good Afternoon, <br /> Attached you will a revised scope of work for the anticipated repairs at the above referenced site. In addition,there are <br /> cut sheets attached for the deflection plates for the Encore 500 dispensers on site that will be used in the repairs. The <br /> technician's ICC and Bravo certifications for this equipment have already been provided. <br /> To sum up the scope of work: <br /> o Prep the following chase pipes and install 3"-2" smith reducer fittings with test ports <br /> 0 91 STP to 91 Fill chase pipe <br /> 0 87 STP to 87 Fill chase pipe <br /> o Diesel STP to Diesel Fill chase pipe <br /> o Remove 6 old boots from the 3 chase pipes <br /> o 2 boots from each existing chase pipe <br /> o Hook the 91-chase pipe to the existing 91 VPH zone <br /> o Hook the 87 Chase pipe to the existing 87 VPH zone <br /> o Hook the diesel chase pipe to the existing diesel VPH zone <br /> o Inspect new fittings with agency and show chase pipes are being monitored under vacuum as part of the VPH <br /> monitoring system <br /> o New sensors should not need to be added. Current zones at this site should allow for the changes we are <br /> proposing. <br /> o Document these new changes on site <br /> o All 6 UDC's <br /> o One by one open UDC's lower cabinet doors <br /> o Remove both sides <br /> o Prep lower cabinet for install of the bravo DEFLECTION PLATES per the submitted cut sheets <br /> o Install [2] Bravo-encore-deflection-plates under each UDC, [one plate for each side of UDC <br /> o These are attached per the install instructions we have submitted "supplied by the manufacture"these <br /> are to remain in place at all times. <br /> o After install, inspect with agency <br /> o After all 6 UDC's have deflection plates installed wipe work areas clean and take pictures for proper <br /> documentation <br /> ? Close up all 6 UDC's <br /> I hope that these modifications will address the outstanding compliance issues and is sufficient for a permit to be <br /> issued. Please let me know if there are any further items that need to be addressed. <br /> Once again, thanks for your help. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.