Laserfiche WebLink
Monitoring System Certification-Page 2 of 3 <br /> Site Address: 4219 Morada Ln. - Date of Testing/Servicing: )!/20/17 <br /> D. Results of Testing/Servicing <br /> Software Version Installed. 327.04 <br /> Complete the following checklist: <br /> 10 Yes ❑ No* I Is the audible alarm operational? <br /> ® Yes D No* Is the visual alarm operational? <br /> ® Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ® Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ® Yes ❑ No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem) <br /> D N/A operational? <br /> ® Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> D N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) ® Sump/Trench Sensors; ® Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 0 Yes ❑ No <br /> ® Yes D No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> D N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating roperly7 If so,at what percent of tank capacity does the alarm trigger? 90 % <br /> D Yes* ® No Was any monitoring equipment replaced7 If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ® Yes* D No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product;® Water. If yes,describe causes in Section E,below. <br /> ® Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, i licable. <br /> ® Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Replaced TLS battery for PM purposes. <br /> Tested all Estops all Passed. <br /> All Sumps& UDC's are monitored by additional Brine Sensors (794380-304) -Tested & Passed. <br /> Vent Sump Sensor(794380-208) & (794380-304)-Tested & Passed. <br /> 91 &Diesel are Spilt Tanks and Share Annular. <br /> Removed Small Amount of Water from all STP and FIII Sumps. <br />