My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORADA
>
4219
>
2300 - Underground Storage Tank Program
>
PR0524617
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2019 2:08:44 PM
Creation date
11/8/2018 9:46:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0524617
PE
2351
FACILITY_ID
FA0016523
FACILITY_NAME
AISLE 1 #2356
STREET_NUMBER
4219
Direction
E
STREET_NAME
MORADA
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12429017
CURRENT_STATUS
01
SITE_LOCATION
4219 E MORADA LN
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MORADA\4219\PR0524617\COMPLIANCE INFO 2017 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2017 - PRESENT
QuestysRecordDate
6/5/2018 9:28:19 PM
QuestysRecordID
3909979
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
300
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California Environallentall Reporting SVstem(CERS) Underground Storage Tank-Monitoring Plan <br /> Facillty/Site <br /> RALEYS FUEL STATION#356 us-,-.,ni, <br /> ens to <br /> 4219E MORADA LN TA0515787 I01$51$3 <br /> STOCKTON,CA 95212 Tank Into:installed Date:2/1120T712.03,00 AM-Tank Ula:Motor Vehicle Fueling-Tank <br /> Commit Regular Unleaded Type Of Tank:oouMe Wall Piping Construction:Double <br /> — — walled <br /> Pipe Monitoring is Performed Using the Following Methods) <br /> yes Ccornuws .notto-,of Ppm,S cordary Com atn,, <br /> P,pm„Secondary Containment Panel Manufacturer leak Sensor Manufacturer <br /> Dry Veeder Root Veeder Root <br /> Panel Model g Leak Sensor Model g <br /> TLS 350 209,304,463 <br /> h Leak Alarm Triggers Automatic Pump Shutdown <br /> es Failure/Disconnect Triggers Pump Shutdown <br /> Mechanical Une Leak Detector Perform'3 GPX Leak Test <br /> Mi Manufacturer FILM Model <br /> Yes Electronic Une Leak Defector Performs 3 GPX Leak Test <br /> LLD Manufacturer ELLD Pmgrarnmed tnAme Tasting ELLD Trial Automatic Pump Shutdown <br /> eeder Root Yes <br /> LLD Model ELM Failure/Disconnect Triggers Automatic Shutdown <br /> 48450 yes <br /> Pipeline Integrity Testing Visual Pipeline Monitoring ----- <br /> Pipeline Integrity Testing Frequency Visual Pipeline Monitoring FrequencyFv^ $� J '._� <br /> her � <br /> DdnDGDg ._a� <br /> Suction Piping Meets Eaempi Criteria <br /> Na Regulated Piping Per Health and Safety Codn.plvlsion 20,chaplet 63 Is Connected To The Tank Status. <br /> other Pipeline Monitoring 'TAL HE LTH <br /> �Ap <br /> oder Dispenser Containment(UDC)Monitoring <br /> JoicMonRoring Detection of Leak into UDC Triggers Audible and Visual Alarms <br /> ntlnuous Yes <br /> UDC Leak Alarm Triggers Automatic Pump Shutdown <br /> OC Panel Manuta6urer Yes <br /> leader Root Fad.n.,oiscomendoon of UDC Monitoring System Tossers Autumatic Pump Shutdown <br /> DC Panel Model Is Yes <br /> rLS-350 UOC Monitoring Stops Flaw of Product at Dispenser <br /> OC Leak Sensor Manufacturer <br /> eeder Root uoc coaammen <br /> DC Leak Sensor Model Double-walled <br /> 1794380-208&304 UDC secondary Contalnment Monitoring <br /> Liquid <br /> Leak Within Secondary Containment of UGC Causes Audible and Visual Alarms <br /> Yes <br /> F, riodlc System Testing <br /> EtO Tesainj <br /> SemnJary Cor[amm t nmg <br /> es S Ill Bucket Testin <br /> Printed on 8/15/2017 8:42 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.