Laserfiche WebLink
36" DIA. MULTI—PORT DUAL POINT FILL SPILL 8 4" X 3" VAPOR RECOVERY ADAPTER & 42„ DIA. FILL SPILL CONTAINMENT 7 <br /> CONTAINMENT ASSEMBLY W/ (2) 5 GALLON 15 CAP IN SPILL CONTAINMENTECOVRYFILL BOX, ASSEMBLY W/ (1) 5 GALLON <br /> SPILL BUCKETS. CARB STAGE I EVR COMPLIANT PER CARE EVC , NO DRAIN VALVE SPILL BUCKET <br /> PER VR-101 16 <br /> TO BE INSTALLED ON VAPOR RECOVERY <br /> 18" SPILL BUCKET. (TYP.) <br /> 18" y <br /> 1-1/2" MIN. CROWN (TYP.) TO 6" 5 GALLON SPILL CONTAINER. / " (TYp,) <br /> TO 6" 1-1 2 MIN. CROWN TO 6" 5 GALLON SPILL CONTAINER WITH <br /> (TYP. ALL OPENINGS) (INLINE DRAIN ON FILL BUCKET ONLY) (TYP. ALL OPENINGS) INLINE DRAIN. <br /> ° ° <br /> d d d d <br /> 3" PEA-GRAVEL MIN. TO PREVENT d ° ; 3" PEA-GRAVEL MIN. TO PREVENT a ; <br /> PA° <br /> HYDROSTATICMP R _ <br /> SU RESERVOIR AND <br /> LOAD TRANSFER TO TOP OF TANK � � 37 LOAD TRANSFER TO TOP OF TANK � r 43 HYDROSTATIC SUMP RESERVOIR <br /> MONITOR AND MONITOR <br /> STATIC GROUNDING 4" FILL ADAPTER AND — STATIC GROUNDING NOB s ' lloL�1 ) <br /> 4" FILL ADAPTER AND 10 CAP IN SPILL 10 t' FOODS <br /> CAP IN SPILL CONTAINMENT FILL BOX t 1 <br /> CONTAINMENT FILL BOX 11 T <br /> 17 17 <br /> J BOX <br /> J BOX <br /> NtiCTS <br /> CONDUIT PENETRATION 25 CONDUIT PENETRATION 25 4" BLACK STEEL RISER <br /> FITTING (TYP.) 4" BLACK STEEL RISER FITTING (TYP.) <br /> TANK GAUGE MONITORING 31 <br /> CAP AND RING KIT 4 42" DIA. DOUBLE WALL CONTAINMENT TANK GAUGE MONITORING <br /> SUMP WITH BRINE FILLED ANNULUS CAP AND RING KIT 31 4" PLUG 500 WEST CAPITOL AVENUE <br /> 111 L, WEST SACRAMENTO, CA <br /> SUMP MONITORING 34 13 4"X4 X2" EXTRACTOR BITTING & 42" DIA. DOUBLE WALL 4 95605 <br /> LIQUID SENSOR _ _ _ ___ BALL FLOAT SET AT 987o CAPACITY CONTAINMENT SUMP WITH ____ _ ______ <br /> 14 BRINE FILLED ANNULUS P.O. BOX 15618 SACRAMENTO, CA <br /> 95852 <br /> - — — - SUMP MONITORING - — — — — — - <br /> ROBE LIQUID SENSOR 34 E3 REVISIONS <br /> Y <br /> 33 TANK <br /> VEEDERLEVEL <br /> ROOpROBEPW/MEVR AG PCAP & <br /> STRAIGHT DROP TUBE 12 RING. OVERFILL ALARM SET ® 90% STRAIGHT DROP TUBE 12 � <br /> H MAG <br /> CAPACITY 33 PROBER TANK <br /> OOTLEVEL PPROBE W/ <br /> EVR CAP & RING. OVERFILL <br /> Fill Side Sum Section a Gasoline Tanks 3 Fill Side Sump Section Diesel Tank ALARM SET ® 90% CAPACITY <br /> 1 !®� <br /> SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0" <br /> 16" � <br /> W VI(If N w �GHACiS <br /> mP �Z <br /> Ckf <br /> �, � Z <br /> Of <br /> 4 42" DIA. CONTAINMENT SUMP ANDm 4 42" DIA. CONTAINMENT SUMP AND <br /> COLLAR WITH BRINE FILLED ANNULUS cr COLLAR WITH BRINE FILLED ANNULUS <br /> ® o <br /> TANG ENG\NFF <br /> / 4" PLUG <br /> ti "LAND PLANNING AND DESIGN SPECIALISTS" <br /> 18215 72ND AVENUE SOUTH <br /> CC <br /> ' (425) `251 -62ZZ <br /> O 0 L KENT, WASHINGTON 98037_ <br /> y <br /> 13 4"X4"X2" EXTRACTOR FITTING & L ® SHEET TITLE <br /> BALL FLOAT SET AT 98% CAPACITY <br /> 0 <br /> 14 0 0 <br /> TANK FILL SUMP <br /> 0 0Oa®oA p ® <br /> VEEDER ROOT .1 GPH MAG PROBE = INSTALL DETAIL, <br /> 33 SUMP MONITORING LIQUID <br /> SUMP MONITORING LIQUID TANK LEVEL PROBE W/ EVR SENSOR CAP & 34 <br /> SENSOR 34 RING. OVERFILL ALARM SET ® 90% 33 VEEDER ROOT .1 GPH MAG PROBE ? <br /> CAPACITY TANK LEVEL PROBE W/ EVR CAP & <br /> RING. OVERFILL ALARM SET ® 90% .r <br /> CAPACITY <br /> M <br /> QaoFeas <br /> A / m <br /> 14 fn <br /> 613ol 67 �4x � BCE #12004 <br /> Fill Side Sump Plan View Gasoline Tanks Fill Side Sump Plan View a Diesel Tank r <br /> SCALE: 3/4" = V-0" SCALE: 3/4" = 1'-0" I `L ® PROJECT NAME <br /> . <br /> t &`` <br /> —_____ _ ___ _____ __ _ _ ___-____--_— <br /> RALETS T, <br /> NOTE: SUMP IS DW FROM TANK SURFACE INTO ____��� TOP OPENING AVAILABLE IN EITHER { I ' #356 <br /> THE ACCESS OPENING. 32" I.D. OR 36" I.D. I SECONDARY FIELD LAY-UP <br /> .. <br /> SUMP TOP <br /> MYLAR <br /> PRIMARY FIELD LAY-UP <br /> MONITORING RESERVOIR <br /> MONITORING RESERVOIR a, <br /> FRONTAGE ROAD & <br /> _ _ SUMP BODY I k MORADA LANE <br /> �00 �J00 I i STOCKTON, CALIFORNIA <br /> TEST FITTING <br /> I <br /> SUMP BODY I ' <br /> �' I I � PROJECT NO. <br /> ' 2.3208.000 <br /> I <br /> - - - - -- - - ------ --- t <br /> r ----- - - - - ----- - - --.-- --- - ------ <br /> ---- -- - - -------- ---- -- - --- -------- <br /> 0 E. DRAWN BY <br /> 42" DE OR 48 WIDEINSIDE FIELD LAY—UP OUTSIDE FIELD LAY—UP i JOINT DETAILS TEST FITTING ' SUMP BODY i <br /> O — I <br /> I 1D o <br /> I <br /> �' I I CONTRACTOR TO ADDITIONALLY GLASS WRAP & LAMINATE AT 42" DE OR 48 WID7 1E , I <br /> COLLAR I I I SCALE <br /> CONNECTION FOLLOWING CURING OF ADHESIVE. SPECIFIC 24" OR 48" I <br /> j I ATTENTION MUST BE GIVEN TO SURFACE PREP AS TESTING PIPING AREA I AS SHOWN <br /> C LLAR BON REQUIREMENTS WILL DETECT THE SMALLEST OF FLAWS. ALL I <br /> TO TANK TANK WALL I FACTORY LAY-U FACTGRY LAY-UPI MATERIALS MUST BE COMPATIBLE WITH GASOLINE, GASOLINE I <br /> I I WITH 15 GASOLINE WITH 10 % ETCH. FIBERGLASS AND RESIN - - -- - - - - -- - - 1 TANK WALL ° INSIDE FIELD LAY-UP OUTSIDE FIELD LAY-UP I <br /> - ---------- - -------� I I I I I • DATE <br /> I I I MUST EXTEND 1/2" BEYOND COVERAGE OF ADHESIVE. ___ _ _ _ _ ______ _ _____+ _-----i i 23 JUNE 2005 <br /> ` I I --- ------ I <br /> 4" COLLAR --------- - - - - --- -- -- -- ---- - J --- - COLLAR I <br /> *NOTE: 4" COLLAR I <br /> PAGE NO. <br /> - PIECE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR 2— PIECE I I <br /> PROPER INSTALLATION & PREPARATION PER FACTORY LAY-UP FACTORY LAY-UP <br /> MANUFACTURERS INSTRUCTIONS AND SHALL I <br /> 7 Flat Sided Fill Sump Riser REINSTALL SUMPS IF HYDROSTATIC TESTING I j TK3 2 <br /> SHOWS LEAKING IN THIS AREA OF THE SUMP. I . <br /> SCALE: NOT TO SCALE <br /> SHEET OF <br /> �w, <br />