COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2021 11:01:14 AM
Creation date
11/8/2018 9:46:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MYRTLE\2849\PR0538822\COMPLIANCE INFO 2018 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2018 - PRESENT
QuestysRecordDate
4/13/2018 5:07:30 PM
QuestysRecordID
3854464
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
y� <br /> UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection ®36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10642219 10/12/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As.) <br /> Regional Transportation Center(Stockton RTD) <br /> Business Site Address City ZIP Code <br /> 2849 E. Myrtle St Stockton 95205 <br /> 11. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Eric Mol card 209 367-4800 Ext. <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 774802 1 8881020 02/25/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method Used: ❑ Manufacturer Guidelines(Specify) <br /> ® Industry Code or Engineering Standard(Specify) PEI/RP1200-17 <br /> ❑ Engineered Method(Specify) <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages: 11 <br /> Tank ID: (By tank number,stored product,etc.) T-1, 40k- Dsl T-2, 40k, Dsl T-3, 101k, Gas <br /> What is the tank inside diameter?(Inches) 120 120 92 <br /> Is the fill piping secondarily contained? ®Yes ❑ No ®Yes ❑ No ®Yes ❑ No ❑Yes ❑ No <br /> Is the vent piping secondarily contained? ®Yes ❑ No ®Yes ❑ No ®Yes ❑ No ❑ Yes ❑ No <br /> Veeder Root OPW Veeder Root <br /> Overfill Prevention Equipment Manufacturer(s) <br /> OPW Veeder Root OPW <br /> What is the overfill prevention equipment ® Shuts Off Flow ®Shuts Off Flow ®Shuts Off Flow ❑Shuts Off Flow <br /> response when activated? ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> (Check all that apply.) <br /> ®AN Alarm 0 A Alarm 0 A Alarm ❑AN Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes ® No ❑Yes El No ❑Yes ®No ❑Yes ❑ No <br /> At what level in the tank is the overfill prevention 106 106 80 <br /> set to activate?(Inches from bottom of tank.) <br /> What is the percent capacity of the tank at which 94 94 94 <br /> the overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating ®Yes M Yes ®Yes ❑Yes <br /> condition to respond when the substance ❑ No ❑ No [01N o ElNo <br /> reaches the appropriate level? (Specify in section V.) (Specify in section V.) (Specify in section V.) (Specify in section V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results FF® Pass ❑ Fail ® Pass ❑ Fail I ® Pass ❑ Fail ❑ Pass Fail <br /> V. COMMENTS - .:.. <br /> All items marked"Fair'must be explained in this section. Any additional comments may also be provided here'- <br /> The following levels and percentages are for the testing with AN Alarm rocess� <br /> Tank 1: level = 100" and percent = 90% NOV 2 <br /> Tank 2: level = 100" and percent = 90% <br /> Tank 3: level = 77" and percent = 90% ENV is <br /> r,nnlnr'IPtT�'�L <br /> r' <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,title 23,division 3, <br /> chapter 16,section 2637.2 and all the information contaip herein is accurate. <br /> UST Service Technician Signature <br /> 4 � <br /> If the facility has more compone an this f rm accommodates,additional copies of this page may be attached. <br /> CEPS=Cafifornia Environmental Reporting System ID=Identification,UST=Underground storage tank,ICC=International Code Council,AX=Audible and visual <br />