My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
2300 - Underground Storage Tank Program
>
PR0231532
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2022 11:21:35 AM
Creation date
11/8/2018 9:47:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY FOOD & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
03
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\C\CAMBRIDGE\16470\PR0231532\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
10/22/2012 8:00:00 AM
QuestysRecordID
131132
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
993
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIT(- LING SYSTEM CERTF43ATION <br /> CERTIFICATION / TEST DATE: June 12, 2009 <br /> A1. FACILITY A2. OWNER <br /> Name Circle K#2701205 Name Circle K Stores, Inc. <br /> Address 16470 Cambridge,Lathrop,CA 95330 Address 495 East Rincon St.,Ste 150, Corona, CA 92879 <br /> Phone# 209-858.4116 Phone# 951-270-5183 <br /> Contact Rex Abacan Contact Rex Abacan <br /> F. IN-TANK GAUGING /SIR EQUIPMENT: ❑ Check this box if tank gauging is used only for Inventory control. <br /> ❑ Check this box if no tank gauging or SIR equipment Is installed. <br /> This section must be completed if in-tank gaugung equipment is used to perform leak detection monitoring. <br /> Complete the following checklist: <br /> ❑ Yes ❑ No* Has all Input wiring been Inspected for proper entry and termination,including testing for ground faults? <br /> ❑ Yes ❑ No a Were all tank gauging probes visually Inspected for damage and residue buildup? <br /> ❑ Yes ❑ No' Was accuracy of system product level readings tested? <br /> ❑ Yes ❑ No' Was accuracy of system Water level readings tested? <br /> ❑ Yes ❑ No' Were all probes reinstalled property? <br /> ElYes ❑ No' Ware all Items on the equipment manufacturers maintenance checklist completed? <br /> In Section H below,describe how and when these deficiencies were or will be corrected. <br /> G. LINE LEAK DETECTORS (LLD): ❑ Check this box if LLDs are not installed. <br /> Complete the following checklist: <br /> ❑ Yes ❑ No* For equipment start-up or annual equipment certification,was a leak simulated to verify LLD performance? <br /> ❑ WA (check all that apply) S/mulatedleakrate: ■ 3g.p.h.; ❑ 0.1 g.p.h.; ❑ 0.2 g.p•h. <br /> ❑ Yes ❑ No' Were all LLD*confirmed operational and accurate within regulatory requirements? <br /> ❑ Yes ❑ No* Was the testing apparatus properly calibrated? <br /> ❑ Yes ❑ No' For mechanical LLDs,does the LLD restrict product flow If It detects a leak? <br /> ❑ N/A <br /> ❑ Yes ❑ No' For electronic LLDs,does the turbine automatically shut oft If the LLD detects a leak? <br /> ❑ N/A <br /> ❑ Yes ❑ No` For electronic LLDs,does the turbine automatically shut off If any portion of the monitoring system Is disabled <br /> ❑ WA or disconnected? <br /> ❑ Yes ❑ No• For electronic LLDs,does the turbine automatically shut off If any portion of the monitoring system malfunctions <br /> ❑ WA or fails a test? <br /> ❑ Yes ❑ No' For electronic LLDs,have all accessible Wiring connections been visually Inspected? <br /> ❑ WA <br /> ❑ Yes ❑ No* Were all Items on the equipment manufacturers maintenance checklist completed? <br /> In Section H below,describe how and when these deficiencies were or will be corrected. <br /> H. COMMENTS <br /> ®7008 Walton Engineering,Inc. <br /> Page 3 of 3 <br />