My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
2300 - Underground Storage Tank Program
>
PR0231532
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2022 11:21:35 AM
Creation date
11/8/2018 9:47:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY FOOD & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
03
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\C\CAMBRIDGE\16470\PR0231532\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
10/22/2012 8:00:00 AM
QuestysRecordID
131132
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
993
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Faolay ection <br /> Circle K Store#1205 AddresFacilitys <br /> Ins16470 Cambridge Road, Lathrop Date: Oct 14, 2011 <br /> Name: Address. <br /> VIOLATIONS <br /> # C1 C2 M I Code Section HSC=CA Health and Safety Code;CFR=Cade of Fedeml Regulations <br /> C1=Class 1 violation C2=Class 2 violation;M=Minor violation <br /> On Site Records(continued) <br /> 204 CCR 2715(.) Designated operator monthly inspection:(1)alarms not documented;(2-4)spill containers,UDCs,and sumps <br /> if necessary)not inspected; 5 required test dates not checked or noted; 6 employee training not verified <br /> 205 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br /> 206 - CCR 2715(f) Designated operator employee training(1 not performed;(2)not current for at least one employee on site; <br /> 3 log not kept <br /> 207 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 302 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment(M1) <br /> 303 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (M1) <br /> 304 CCR 2632(.)(2) Monitoring system is not present in the interstitial space of a double walled UST (M1) <br /> 305 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates an (M1) <br /> audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 306 CCR 2631(a) Primary containment is not product fight <br /> 307 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 308 CCR 2636(.)(1) All releases in secondary piping do not flow to a collection sump <br /> 309 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) (112) <br /> 310 HSC 25291(a) Water in 2-containment not removed,analyzed&property disposed of <br /> 311 CCR 2636(f)(2) Line leak detector(s)not installed or failed to detect a 3-gallon per hour leak at 10 psi (Mt) <br /> 312 CCR 2635(b) No spill container or overfill prevention system installed (102) <br /> 313 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means to keep (102) <br /> the spill container empty <br /> 314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements (M2) <br /> 315 HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br /> 316 CCR 2631.1(a) UST system is not compatible with the substance stored <br /> 317 HSC 25298(a) Illegally abandoned UST system <br /> Aa 1702(2003-2004) HSC 25290.1 (Installed between 07101103 and 06130104) <br /> VPH System HSC 25290.1 installed on or after 07101104 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance stored;(b) <br /> 401 CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b)and(d) <br /> for a UST system installed after Jul 1,2004,were not submitted <br /> 402 HSC 25290.1(.)(1) primary containment not liquid or vapor tight <br /> HSC 25290.2 c 1 <br /> 403 HSC 25290.1(.)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2 c 2 <br /> 404 HSC 25290.1(c)(3) <br /> HSC 25290.2(c)(3) Secondary containment not constructed to prevent water intrusion <br /> 405 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the entry of <br /> HSC 25290.2(d) liuid or vapor from the rima containment into the seconds containment <br /> 406 HSC 25290.1(a) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space of the <br /> UST s tem not maimained <br /> 407 HSC 25290.1() UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2)inert gas <br /> HSC 25290.2pressure test approved by SWRCB; 3 test method deemed a uivalent t0 1 or(2)by the SWRCB <br /> Emergency Generator Systems <br /> 501 CCR 2636(f)(6) Emergency generator monitoring system not checked daily or log not kept if no leak detector (M1) <br /> 502 HSC 25281.5(b)(3) Unburied fuel piping not visually inspected at least monthly or log not kept (M1) <br /> USTs In a Vautt <br /> 601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br /> 602 HSC 25283.5(a)(2) Structure that the UST is located in does not provide for secondary containment <br /> 603 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br /> 604 HSC 25283.5(a)(5) UST installed after July 1,2003,does not meet or exceed applicable sections of HSC 25291 <br /> Non-Pressurized Piping <br /> 701 CCR 2843(d) Daily monitoring of suction piping(pre-January 1,1984)not performed (Mt) <br /> IFt7ur Roceived By: r tle. Off` <br /> Thuy Tran (209) 468-8257 lr\� --�� <br /> EHD 23-02 Rev 09/01/11 P UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.