My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
2300 - Underground Storage Tank Program
>
PR0231532
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2022 11:21:35 AM
Creation date
11/8/2018 9:47:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY FOOD & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
03
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\C\CAMBRIDGE\16470\PR0231532\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
10/22/2012 8:00:00 AM
QuestysRecordID
131132
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
993
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l s q_3 <br /> S WRCH,January 2002 Page_L of_ <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sum <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer 31ndustry Standard 0 Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: 0 Pressure 0 Vacuum 9 Hydrostatic <br /> 0 Other(Spec) <br /> Test Equipment Used: INCON TS-STS Equipment Resolution: .000 i n. <br /> Fill Sum # Fill Sum # Fill Sump# Fill Sump# <br /> Sump Diameter. <br /> Sump Depth; <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sump prior to <br /> testi <br /> Portion of Sump Tested <br /> Sump Material: <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> startin test. UIN` <br /> Test Stag Time: <br /> Initial Readin <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: _ <br /> Chane in Reading R <br /> -Pass/Fail Threshold or Criteria: <br /> Teat Result: n Pala O Fail 0 Pass 0 Fail 0 Pass 0 Fail 0 Paas 0 Fail <br /> Is there a sensor in the sump? 0 Yes Cl No 1 0 Yes 0 No ❑Yes 0 Nc 0 Yes ONo <br /> Does the sensor alarm when <br /> either product or water is OYes ONo ONA ❑Yes ONo DNA ❑Yes ONo ONA OYes 0No ONA <br /> detected? <br /> Was sensor removed for testinKe 10Yes 0 N 0 N ❑Yes 0 N 0 N OYes ONo 0 N ❑Yes ONo DNA <br /> Was sensor properly replaced and 0Yes ONo ONA OYes ONo ONA ❑Yes ONo ONA OYes ONo ONA <br /> verified functional after testing? <br /> COOLIntlits—(include information on repairs made for to testing and recommended ollow-u or ailed resfs <br />
The URL can be used to link to this page
Your browser does not support the video tag.