Laserfiche WebLink
MONITi"RING SYSTEM CERTIFIC 1TION <br /> ,_,Jae By All Jurisdictions Within the State of Califoml <br /> Authority Cited.,Chapter 6.7,Has/th and Safety Code;Chapter 16,Division 3 Title 23, L'aafomia Code of Regulations <br /> This forth must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> oertification or report must be prepared for each monitorina system control panel by the technician who performs the work. A copy of this forth must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this forth to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CIRCLE K 2701205,CO.123 City: LATHROP CA Zip:95330 <br /> Site Address: 16470 CAMBRIDGE Contact Phone No: 658-4116 <br /> Date of Testing/Service: 04/15/2005 <br /> Facility Contact Person: MANAGER <br /> Make/Model of Monitoring System:TLS-350 Work Order Number: 2235066 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment Inspected/serviced <br /> Tank ID: 1.87 Tank ID: 2-91 <br /> X In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 409 Annular Space or Vault Sensor. Model: 409 <br /> X Piping Sumprrmnch Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: MLD <br /> Mechanical Line Leak Detector. Model: MLD <br /> Electronic Line Leak Detector, Model: Electronic Line Leak Detector. Model: <br /> Tank OverfilLfHigh-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> TanklD: TanklD: <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sumprrmnch Sensor(s). Model: Piping SumpRrench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: 7 Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: 7 Electronic Line Leak Detector. Model: <br /> Tank Overfill/HigtFLevel Sensor. Model 7 Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Sectlon E on page 2). 7 Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> ❑Dispenser Containment Sensor(s) Model: 7 Dispenser Containment Sensor(s) Model: <br /> X❑Shear Valve(s). X Shear Valve(s) <br /> ❑X Dispenser Containment Floats)and Chain(s). -X-1 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chemist. Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser 10: <br /> Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Valve(s). <br /> ElDispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ❑System set-up X❑Alarm history report <br /> Technician Name(print): DOUGLAS HARTY Signature: <br /> Certification No.: 006-05-0253 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servidng: 04/15/2005 <br /> Page 1 of 3 Based on CA form dated 03/01 <br /> Monitoring System Certification <br />