COMPLIANCE INFO 1990 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO 1990 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:21 AM
Creation date
11/8/2018 9:47:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990 - 2008
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 1990 - 2008 .PDF
QuestysFileName
COMPLIANCE INFO 1990 - 2008
QuestysRecordDate
11/16/2016 9:54:06 PM
QuestysRecordID
3259375
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
413
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEP-3-2006 10:17A FROM:MVP PETROLEUM ENGINE 916 984 -1117 "1:12094683433 P.3 <br /> �i*OPW 61T FILL DROP TUBES <br /> The DPW 61T Drop Tube is installed In the fill riser pipe to an underground storage ; <br /> tank. It Is designed to transfer product from the fill connection point(between the <br /> delivery drop elbow and tight-fill adaptor)to within 6'(or per local requirements)of the <br /> bottom of the tank. This allows for submerged filling of the tank,resulting in a more <br /> efficient delivery flow rate white reducing the bulid-up of vapors or foam In the tank. <br /> Features: Ordering Specifications <br /> ♦ .052"Thick Drop Tube Walls- Drop Tube a <br /> Deter denting and damage to the Length qC9 <br /> tube upon installation or removal far Product No. In. mm. lbs. kg. ft. m. <br /> long service life. SIT-7244 3" 76 3.14 1.43 10 3.05 <br /> o <br /> ♦Various Lengths and Diameters- 61T-3015 3" 76 4.5 2.04 15 4.57 <br /> Accommodate a variety of tank 61T-7266 4" 102 5.12 233 10 3.05 _ OPW61T <br /> diameters and rill riser pipe sizes. , 61T•72fi8 /" 102 8.16 2.80 12 3.68 <br /> 4, toe 61T-7368 4" 102 7.65 3.48 15 4.57 1 1 p <br /> 617.7468 4" 102 13 5.9 17 5.19 <br /> 91T•f012' 4" 102 10.76 4.66 12 3.88 <br /> 'Grooved tube wweeww•wnx <br /> Replacement gaskets for the 61T-4'and the 61 SO Sodas <br /> are available.Order the OPW 61TG(4000). <br /> OPW 61TC COAXIAL FILL DROP TUBES <br /> The DPW 61TC Coaxial Drop Tube is designed to replace an DPW 61T Conventional <br /> Drop Tube when Stage I Vapor Recovery is required and a vapor recovery riser pipe s - <br /> Is not available on the tank or would require excavation to the top of the tank. The 19�2�0 eer a , <br /> 61TC is used in conjunction with OPW 633TC Coaxial Vapor Recovery Adaptors to <br /> return vapors to the tank truck,through one riser pipe,during a fuel delivery to an 634TT <br /> underground storage tank. The upper section of the 61TC is tapered to allow vapors <br /> to return to the tank truck through the Interstitial space between the riser pipe and out- 633M or <br /> side wall of the drop tube. Simultaneously,product Is delivered to the tank through , + S=P <br /> the center of the 61 TC. �,•r•.. `-=o•N•;-ems. <br /> eat'I oagar�U.. <br /> .14Z. <br /> OPW 61TCP POPPETED COAXIAL FILL DROP TUBES a�•:!<. ;°e TCP <br /> y,t <br /> The DPW 61TCP Poppeted Coaxial Fill Drop Tube is similar to the 61TC,but is ;.;;. <br /> spring-loaded. When used In conjunction with the OPW 633TCP,the 61TCP acts as a <br /> poppet to close oft the vapor return side of the coaxial fill tube.(Adaptor not Included) 1i:.0 <br /> d Khan Pipe <br /> Features: ia3 d' ~bs4 iY <br /> ♦ .052"Thick Drop Tube Walls- ' k0...1 <br /> Deter denting and damage to the underground <br /> tube upon Installation or removal for Tank <br /> long service life. <br /> o Various Lengths and Diameters- Ordering Specifications <br /> Accommodate a variety of tank <br /> diameters and fill riser pipe sizes. Product No. Diameter Length welght ut1 <br /> o Fully Welded Retaining Brackets- I". 76 3 M. Ilia. .0 Pdn <br /> Ensure a secure Installation in the s1TC•1186 3° TB 13' 3.D8 8.75 3.00 <br /> riser pipe. 61TC-7270 4° 102 13' 3.05 9.64 3.93 <br /> o Three Centering Springs-Enable 61TC-7272 P 102 Ir 4.86 13.62 6.28 <br /> even flow of vapors back to the 61TCP-3800 4° 102 1r 3.06 8.86 4.07 <br /> tank truck. <br /> y <br /> North America Toll Free-TELEPHONE:(800)422.2525•Fax:(8001421.3297•Email:domeslksalesRopw-fe.com <br /> ^ <br /> \J P VV-* International-TELEPHONE:(5131970.3315 or(513)870.3261•Fax:(513)870.3157•Email:In%ales®opw-Ie.com -" <br /> w .opw-fc.com t <br /> °O�"-°°"""` 0 Copyright 2003,OPW Fueling Components•P.O.Box 405003•Cincinnati,OH 45240-5003•Printed in USA+3103 t <br />
The URL can be used to link to this page
Your browser does not support the video tag.