My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1990 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO 1990 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:21 AM
Creation date
11/8/2018 9:47:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990 - 2008
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 1990 - 2008 .PDF
QuestysFileName
COMPLIANCE INFO 1990 - 2008
QuestysRecordDate
11/16/2016 9:54:06 PM
QuestysRecordID
3259375
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
413
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQtV,(COUNTY ENVIRONMENTAL HEALTH ARTMENT <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-PAGE I <br /> TYPE OF ACTION ❑.I..NEW PLAN ❑ 2.CHANGE OF INFORMATION mol. <br /> PLAN TYPE ONITORING IS.IDENTICAL FOR ALL USTs AT THIS FACILITY. Mm. <br /> (Check one item only) [3 THIS PLAN COVERS.ONLY TI IE FOLLOWING UST SYSTEM(S): <br /> FACILITYINFORMATION7;uM <br /> FACILITY ID#(Agency Use OW - <br /> FACILITY NAME vvlwk M03. <br /> FACILITY SITE ADDRESS W �.421Fi2 u��Y s1 CITY Stec b.9a J Mos. <br /> D,PREVENTIVE,MAINTENANCE <br /> State law requires that testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)be performed in M°6_ <br /> accardance with the equipment manufacturers'instructions,or annually,whichever is more frequent. Such work must be performed by qualified personnel. <br /> IIS <br /> MONITORING EQUIPMENT IS SERVICED 1.ANNUALLY ❑ 99.OTHER(Specify): NOT <br /> I. MONITORING LOCATIONS <br /> This monitoring plan must include a Site Plan showing the general tank and piping layouts and the locations where monitoring is performed(i.e.,location of each sensor, <br /> line leak detector,monitoring system controt panel,etc.). If you already have a diagram(e.g.,rumen UST Monitoring Site Plan from a Monitoring System Certification <br /> fiann,Hazardous Materials Business Plan map,etc.)which shows all Nuired informmio include it with this plan. <br /> ' ;t TORR <br /> MONITORING IS PERFORMED USING THE FOLLOWING METFIOD(S):(Check all that apply) Mlu. <br /> ❑.l..CONTINUOUS.ELECTRONIC MONITORING OF TANK ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) <br /> SECONDARY CONTAINMENT IS: p'P a..DRY ❑ b.LIQUID FILLED ❑.c.UNDER PRESSURE ❑.d.UNDER VACUUM Ml1. <br /> PANEL MANUFACTURER 60AeIS4Xf MIS. MODEL#: A--,syC M13. <br /> LEAK SENSOR MANUFACTURER: M14. MODEL#(S): MIs. <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANKS) <br /> PANEL MANUFACTURER MI6' MODEL#: MI¢ <br /> IN-TANK PROBE MANUFACTURER Mls. MODEL#(S): M19. <br /> LEAK TEST FREQUENCY: ❑ a CONTINUOUS ❑.b.DARY/MGHTLY ❑ c.WEEKLY Mm. <br /> ❑. d.MONTHLY ❑.e.OTHER(Specify): 0Q1. <br /> PROGRAMMED TESTS: El a.0.1.gp.h. ❑.6.0.2 g.p.h. ❑.c..OTHER(Specify): M1z N11. <br /> ❑.3.INVENTORY RECONCILIATION ❑. a MANUAL PER 23.CCR§2646 ❑ b.STATISTICAL PER 23 CCR§2646.1 MM. <br /> ❑.4.WEEKLY MANUAL TANK GAUGING(MTG)PER 23 CCR§2645 <br /> TESTING PERIOD: ❑.a.36 HOURS ❑ b.60 HOURS. Ms. <br /> ❑ 5.INTEGRITY TESTING PER 23.CCR§2643.1. <br /> TESTFREQUENCY: ❑.a.ANNUALLY ❑. b.BIENNIALLY ❑ c.OTHER(Specify): W6. Mn. <br /> ❑ 6.VISUAL MONITORING DONE: ❑ &DAILY ❑ IS.WEEKLY(Iagw..sme,wwvd) <br /> ❑ 99.01TINR(Specify): nus. <br /> ~PIPCMONITORING <br /> MONITORING 1S.PERFORMED USING THE FOLLOWING METHODS)(Check all that apply) ^43°_ <br /> 1.CONTINUOUS.5L1-CfROMC MONITORING F PIP]NG SUMP(S}rl'RINCH(ES)AND OTEIF,R SECONDARY CONTAQ]MENT <br /> SECONDARY CONTAINMENTS: a.DRY ❑.b..LIQUID FILLED ❑..c.UNDER PRESSURET ❑..d.UNDER VACUUM M31. <br /> PANEL MANUFACTURER: GIL fSA¢ccs E nnz. MODEL#: M'1L AO3. <br /> LEAK SENSOR MANUFACTURER: f. f?A5U'7 MN. MODEL N(S): e4'sv='er Zv Mas <br /> WILL A PIPING LEAK ALARM TRIGGER AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN? ®a YES ❑ b.NO M1C <br /> WILL FAILUREIDISCONNECTION OF THE MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? [&ra YES ❑ IS.NO M7 <br /> MECHANICAL LINE LEAK DETECTOR (NEED) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS. AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS.DETECTED <br /> MLLDMANUFACIURER(s): ZOO nus. MODEL#(S): Mas. <br /> 03.ELECTRONIC LINE LEAK DEl'ECTOR(ELDIt )THAT ROUTINELY PERFORMS.3.0 g.p.h_LEAK TESTS ' ,a ., <br /> ELLD MANUFACTURER: Y.$Rpy,-(,{SS Ma. MODEL#: -+moo(� M4t. <br /> PROGRAMMED LINE INTEGRITY TESTS: ❑.&MINIMUM MONTHLY 0.2 g.p.h. m. IS.MINIMUM ANNUAL 0.1.g.p.h. M42. <br /> WILL ELLD DETECTION OF A PIPING LEAK TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a YES ❑ b..NO MIS. <br /> WILL ELLD FAILURF/DISCONNECTION TRIGGER AUTOMATIC.PUMP SHUTDOWN? ❑ a,YES ❑ IS.NO M01' <br /> ❑.4..INTEGRITY TESTING ���'''���...���$$$ <br /> TEST FREQUENCY: ANNUALLY ❑. b..EVERY 3 YEARS. ❑ c.OTHER(Specify) M45. MM. <br /> ❑.5.VISUAL MONITORING DONE: a DAILY ❑. b.WEEKLY- ❑ C.MIN.MONTHLY&EACH TIME SYSTEM OPERA'T'ED-- M47. <br /> 'RN.nom qn ••.AllowW fw.manirorinrof,nburid eve,gmy emcazo.ted Pipings YWHSC 135281.5(6X3) <br /> ❑ 6.PIPING IS SUCTION PIPING MISTING ALL REQUIREMENTS FOR EXEMPTION FROM MONITORING PER 23 CCR§2636(aX3) <br /> ❑ 7.NO PRODUCT OR REMOTE FILL PIPING IS CONNECTED TO THE UST(s) <br /> ❑ 99.OTHER(Specify) mos. <br /> SJCEHD-d(07/03)-1/4 07/23/03 <br />
The URL can be used to link to this page
Your browser does not support the video tag.