My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1990 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO 1990 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:21 AM
Creation date
11/8/2018 9:47:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990 - 2008
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 1990 - 2008 .PDF
QuestysFileName
COMPLIANCE INFO 1990 - 2008
QuestysRecordDate
11/16/2016 9:54:06 PM
QuestysRecordID
3259375
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
413
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONTINUATION FORM Page: 2 of 2 <br /> uWFICIAL INSPECTION REPORT + Date: 02113/06 <br /> Facility Address: 1789 W. Charter Way Program: UST <br /> #2 Secondary containment testing is due once every 36 months. The last test was performed <br /> on 10-16-02 and was due on 10-16-05. This testing is past due. Immediately schedule this <br /> testing and notify this office at least 48 hours prior to testing. <br /> #6 Monitoring and response plans are required to be kept onsite. A copy of these plans <br /> could not be located at the time of inspection. Immediately provide a copy onsite. <br /> #7 Maintenance and monitoring records are required to be kept onsite. These records could <br /> not be located at the time of inspection. Immediately provide copies onsite. <br /> #10, 12 The presence of a functional UST monitoring system could not be verified. All <br /> power to the store and dispensers were off at the time of inspection. The UST system <br /> must be monitored at all times. Take all necessary action to restore monitoring to the UST <br /> system immediate) . <br /> #18 Spill containers on both tanks contain liquid. Immediately collect all liquid from the spill <br /> containers, determine if it is hazardous, and dispose of it accordingly. <br /> #23 The designated operator shall perform a monthly inspection of the UST system and <br /> provide the owner with a copy of each monthly report. A copy of each monthly report <br /> shall be retained onsite for at least 12 months. No designated operator reports were <br /> available at the time of inspection. Submit a copy of all designated operator inspection <br /> reports for March 2005 through February 2006 immediately. Retain these reports onsite <br /> immediately. <br /> #37 This UST system has been illegally abandoned. No power is supplied to the facility and <br /> the UST system is not being monitored. <br /> 438 The UST system shall be monitored using the method specified on the permit for the UST <br /> system and records of monitoring, testing, repairing and closure shall be kept in sufficient <br /> detail to enable this office to determine if the UST system is in compliance. The UST <br /> system is not being monitored at all and no records are available for review. <br /> NOTE: Submit a copy of the "Return to Compliance" form with a statement of how each <br /> violation has been or will be corrected. Submit by March 14, 2006. <br /> NOTE: Both the tank owner and operator are responsible for the operation and monitoring of the <br /> UST system. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By: Title: <br /> SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT-304 E WEBER AVE,STOCKTON,CA 95202 (209)468-3420 <br /> EHD 23-02-003 <br />
The URL can be used to link to this page
Your browser does not support the video tag.