Laserfiche WebLink
Spill Bucket Testing Report Form SW]fJVuMd006 <br /> This form is intended far use by contractors performing annual testing of UST spill containment structures. The cHaY�lete fo'»n and-_ <br /> printouts from tests(ifapplicable), should be provided to the facility owner/operator for submittal to the local regulatoFyagehay- <br /> 1. FACILITY INFORMATION <br /> Facility Name: PLAZA OASIS I Date of Testing: 3-28-16 <br /> Facility Address: 800 S CHEROKEE LANE LODI CA 95240 <br /> Facility Contact: I Phone: 209-368-0127 <br /> Date Local Agency Was Notified of Testing:2-24-16 <br /> Name of Local Agency Inspector(ifpresent during testing): SAN JOAQUIN CO ARIS <br /> 2.TESTING CONTRACTOR INFORMATION <br /> Company Name: AFFORDA TEST 416 2nd Street Galt,CA 95632 (209)744-0112 Fax:(209)744-0116 <br /> Technician Conducting Test: ❑Lyle D.Nimmo ❑ Zane A.Nimmo M David A.Winkler ❑ Felix G.Ramirez <br /> 5249115-UT 5263322-UT 5263373-UT 5273934-UT <br /> Credentials': M ICC Service Tech. M SWRCB Tank Tester <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: ®Hydrostatic ❑Vacuum ❑Other <br /> Test Equipment Used: TAPE/H2O Equipment Resolution: 1/16 <br /> Identify Spill Bucket(By Tank 1 87 2 91 3 DIE 4 <br /> Number,Stored Product, etc. <br /> ®Direct Bury ®Direct Bury M Direct Bury ❑Direct Bury <br /> Bucket Installation Type: ❑Contained in ❑Contained in <br /> ❑Contained in Sump ❑Contained in Sump SumpSum <br /> Bucket Diameter: 11 i l 1 l <br /> Bucket Depth: 13 13 12 <br /> Wait time between applying <br /> vacuum/water and start of test: <br /> Test Start Time(Ti): 11 11 11 <br /> Initial Reading(Ri): 12 13 11 <br /> Test End Time(TF): 12 12 12 <br /> Final Reading(RF): 12 13 11 <br /> Test Duration(TF—Ti): I HOUR 1 HOUR 1 HOUR <br /> Change in Reading(RF-Rj): 0 1 0 0 <br /> Pass/Fail Threshold or <br /> Criteria: <br /> Test Result: M Pass ❑Fail M Pass ❑Fail M Pass ❑Fail ❑ Pass ❑Fail <br /> Comments—(include information on repairs made prior to testing and recommended fallow-up for failed tests) <br /> OPW BUCKETS <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> I hereby certify that all the information contained in this report is true,accurate,and in full compliance with legal requirements. <br /> Te hnician's Signature: Date3-28-16 <br /> ' State laws and regulations do not currently require testing to be performed by a qualified contractor.However,local requirements <br /> may be more stringent. <br />