My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2802
>
2300 - Underground Storage Tank Program
>
PR0516736
>
COMPLIANCE INFO 2001-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/8/2018 9:48:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2006
RECORD_ID
PR0516736
PE
2361
FACILITY_ID
FA0012764
FACILITY_NAME
SAFEWAY FUEL CENTER #1769
STREET_NUMBER
2802
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2802 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\COUNTRY CLUB\2802\PR0516736\COMPLIANCE INFO 2001-2006.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LG 113 Vendor/Template Page 1 of 2 <br /> ;.Fjy... ,.. VAT <br /> �- <br /> Y <br /> Welcome to <br /> t2 D `Y�1 C� s <br /> Issue Dale:August 28,1998 <br /> Revision Date:April 27,2004 <br /> Veeder-Root <br /> TLS-300, 3001, TLS-350 Series, Red Jacket ProMax and ProPlus with <br /> Discriminating Dispenser Pan Sensor 794380-322, <br /> Discriminating Containment Sump Sensor 794380-352 <br /> INTERSTITIAL DETECTOR (LIQUID-PHASE) <br /> Detector: <br /> Output type: qualitative <br /> Sampling frequency: continuous <br /> Operating principle: product permeable, reed switch/float <br /> Test Results: <br /> *California requires annual certification of all leak detection equipment. The certification of discrim <br /> sensors should include functional testing of both water and product detection capabilities. <br /> Model 794380-322 and 794380-352: Currently the SWRCB UST Program staff discourages the use c <br /> strip discriminating sensors at new installations in California. This is due to concerns about the imp <br /> repeated/prolonged exposure to hydrocarbons may have on the sensor's ability to alarm and recov, <br /> alarm reliably. Since current evaluation protocols do not address this issue, no new polymer strip st <br /> should be installed until new evaluation protocols are in place. <br /> polymer strip Float switch <br /> unleaded gasoline diesel water <br /> Discriminating Dispenser Pan <br /> Sensor 794380-322 high* low* <br /> Response time (sec) —10 min 2-12 hrs <1 <1 <br /> Recovery time (sec) N/A** N/A <1 <1 <br /> Lower detection limit - height (in) N/D** N/D 7.66 1.37 <br /> Lower detection limit - thickness (in) 0.005 0.005 N/A N/A <br /> Discriminating Containment Sump <br /> Sensor 794380-352 <br /> Response time (sec) —10 min 2-12 hrs <1 <1 <br /> Recovery time (sec) N/A N/A <1 <1 <br /> Lower detection limit - height (in) N/D N/D 12.28 1.35 <br /> Lower detection limit- thickness (in) 0.005 0.005 N/A N/A <br /> http://www.swrcb.ca.gov/cwphome/ust/leak—prevention/lgl 13/Vendor_Files/veeder_root_o.h... 6/13/05 <br />
The URL can be used to link to this page
Your browser does not support the video tag.