Laserfiche WebLink
• SAN JOAQUIN COUNTY 0 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Mein Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> t nn IJ kwy qM ( '4� 01-21-10 <br /> # Code Section VIOLATION(S) HSC=Califomia Health&Safety Code;CCR=California Code of Regulations V R <br /> V=Violation;RV=Re eat Violation V <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days;(e)test <br /> 24 CCR 2638 notification not provided to the EHD at least 48 hours prior to conducting an installation,repair,replacement, <br /> calibration,or certification;(f)performed,and failed to affix a tag/sticker on each monitoring equipment <br /> component that was certlfed,repaired,or replaced <br /> 25 CCR 2638 Annual line leak detector test:(a)not performed;(d)test report not submitted within 30 days (M1) <br /> 26 HSC 25284.2 Annual spill containment testing not performed <br /> 27 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present <br /> 28 CCR 2661 Repair for tank or piping not tested for tightness within 30 days of completion of the repair (M2) <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (M1) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1 000'of public well,or failures not repaired and retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) Permit to alter monitoring system not obtained <br /> 34 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 35 HSC 25298(c) Permit to dose UST system not obtained <br /> 36 HSC 25299(a)(9) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned UST system <br /> 38 HSC25281.5 b 2 Unburied fuel piping at marinas not visually inspected at least monthly or log not kept <br /> 39 CCR 2631.1 a UST system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 CCR 2636(f)(6) Emergency generator monitoring system not checked daily or log not kept (M1) <br /> 41 HSC 25281.5(b)(3) Unburied fuel piping not visually inspected at least monthly or log not kept (M1) <br /> VPH System HSC 25290.2 installed between 07/01/03 and 06/30/04 HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance stored;(b) <br /> 42 CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b)and(d)for a <br /> UST system installed after July 1,2004,were not submitted <br /> 43 HSC 252:0.1(C)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2 c 1 <br /> 44 HSC 252990.10.2(c)(2) <br /> HSSecondary containment not liquid or vapor tight <br /> C 252 c2 <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the entry of liquid <br /> HSC 25290.2(d) or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space of the UST <br /> system not maintained <br /> 48 HSC 25290.10) UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2)inert gas <br /> HSC 25290.2(i) pressure test approved by SWRCB;(3)test method deemed equivalent to(1)or(2)by the SWRCB <br /> Other violations <br /> 99 Other: <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD IN CTOR: PHONE: V I UIC <br /> `/'C� U O'� Septic system: <br /> 14 D/rey� Serves 20 people/day <br /> RECEIVED TITLE: C Receives other than sanitary waste <br /> In,(\` Other disposal methods: <br /> iI-Dry wells/French Drains <br /> EHD 23-02-002 REV 12/09 Page 2 UST INSPECTION REPORT <br />