My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2005 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:48:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2010
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99 E
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\10878\PR0231598\COMPLIANCE INFO 2005 - 2010 .PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2010
QuestysRecordDate
5/17/2017 6:13:49 PM
QuestysRecordID
3384372
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY • ! lir- L� O 1 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street,Stockton,California 95202-3029 FhPtj 0.7v-0-2— <br /> Telephone: <br /> 2Telephone:(209)468-3420 Far(209)468-3433 Web.www.sj ov.orRfehd <br /> UNDERGROUND STORAGE TANK UST PROGRAM INSPECTION REPORT <br /> Facility nome: 1(�'�!fJ Designated Operator Inspection Date: <br /> gC.iru, 7� 12 r <br /> Facility address: uy-y d i <br /> Product <br /> Fad tyrjContact: Mile: Pbone; <br /> Mo <br /> Raring Pipingartem: verBll prevention; <br /> W /4� ❑Suction DGrivity WMachanical D AudiblOviwal <br /> 1 peeDon type: Violatioor. <br /> autine onimrin Ce"ifiratien C Installation ❑01her. ❑M I-RDeeeet *1A2-RPnw ❑M-3 Both <br /> q Code Section VIOLATION(S) HSC-Califonia Health&Safety Code;CCR-Califomia Code of Regulations V R <br /> V=Violation;RV-RViolation v <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test perfarrned <br /> 3 CCR 2711 b)& c Current Unified Program Consolidated Fomes on file with EHD(Facility and tank form) <br /> 4 HSC 25292.2 Cwiflration of financial responsibility and CFO letter <br /> 5 CCR 2632 6 Monitoring P (Monitoring&Res se Plan)is current and a ved by the local agency. <br /> 6 CCR 2712 Q Monitoring plan is onsite. <br /> 7 CCR 2712 6 Maintenance&monitoringrecords Ml <br /> 8 CCR.2643 d) Dailymonitoring of auction piping(pre-January.1. 1984) <br /> 9 HSC 25292.1 UST system iso erated to pieveitt unauthorized release <br /> 10 CCR 2632(c) UST monitoring system is present Ml <br /> 1 I CCR 2630 d) UST system monitoring equipment is groperly located to detect a leak M t <br /> 12 HSC 25291 b UST system monitoring equipment is operational M2) <br /> 13 CCR 2636 1 Continuous monitoring tem for underground i in &UDC is t Ml <br /> 14 CCR 2631 a) Primary containment is product tight <br /> S 1 HSC 25291 (a)(2) Secondary containment for UST is light <br /> 16 CCR 2636(c)(1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 Line leak defector(s) are installed Ml <br /> 18 CCR 2635(b)(1) Spill container M2 <br /> 19 CCR 2635 2 Overfill prewntion system M2 <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&r containment <br /> 21 HSC 25291(e) Water in r containment analyzed&properly disposed of <br /> 22 CCR 2650 RceordinWryporfing of unauthorized releases (M I <br /> 23 CCR 2715 Desi ated Operator:(a)Statement from UST owner, (c-c)Moodily inspection; f)Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638 a Annual line leak detector test (M l <br /> 36 NSC 25284.2 Annual spill containment testis <br /> 27 CCR 2636 4) Annual line tightness test (M I <br /> 28 CCR 2661 t) Repair for tankfpipirig has had tightness test M2) <br /> 29 CCR 2643 a Biennial lightness test of gravity pipingno>Jmm 1, 1984) <br /> 30 CCR 2643 d Triennial line test for conventional suction pipin2(pre-January1 1984 (M l) <br /> 31 HSC 25292.5 Double mll system located within IOW'of public well-ELD. <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a) Permit TO alter Monitoring ran <br /> 34 HSC 25298 b) Permit to temporarily dose UST system <br /> 35 HSC 25298 c) Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298 a) Illegal abandonment of UST system <br /> 38 Other. <br /> EHD INSPECTOR: PH Vic <br /> p Vic <br /> r / Zw I / SeMic SVStcm- <br /> '7 `•� t'-a, �'nsc5?Itlpmplr'day <br /> RECEIVED BY: TITLE: -Receives other dun sanitary waste <br /> ,, _ �.�. Orherdisposolrrcehals <br /> -. 4Dry weltslFrench Drains <br />
The URL can be used to link to this page
Your browser does not support the video tag.