My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2005 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:48:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2010
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99 E
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\10878\PR0231598\COMPLIANCE INFO 2005 - 2010 .PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2010
QuestysRecordDate
5/17/2017 6:13:49 PM
QuestysRecordID
3384372
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
02/16/2010 00:16 91b3/;i11/3 WHLIUNtNU1NttK1NU rraut nn <br /> W N1 13iv51 7.wTAOIIVIEIT{ IF <br /> tS` "I <br /> Tact Method'-6.y: 0 Maniifectuier . 4anriueiyatanaara O.-OMf6stidnsllE 1girn` �tfiec(sb*!#1.6w- <br /> 'test; ERNbd(:U est;':r 0 Prossure O dacuum �"Nydrostatic:'... ; .. 'til O.thet-(see.below), <br /> 'Measuring EquipmentMed: MGON TS=STS' jEleCtrdriic Sufhp.TastSy5telri) <br /> Descrl "tion r': Mop* 112: .' 016P4314 ;'., .[. : r:w6 t0a <br /> UDC manufacturer Bravo Bravo Bravo — Bravo <br /> UDC material .. .steel _,. steel _ •Steel _ .Steel <br /> UDC depth (Inches) 9 9 9 g <br /> Height from UDC bottom to highest Bottom - Bottom Bottom Bottom <br /> piping penetration <br /> Height from UDC bottom to lowest Bottom- Bottom Bottom Bottom <br /> electrical penetration <br /> Condition of UDC prior t0 testing Dry _ Dry <br /> Dry ., . <br /> _ .-_. ..-----' Dry.—.. ..—. <br /> Portion of UDC tested Entire ` Endre Entire Entire <br /> _..._. -_. .—_. .. <br /> Type of shut-down present <br /> Float <br /> Float :. Float Float <br /> —' - - .. .. .— --- —' .-- _- .. <br /> Was sensor removed for tasting? NIA -...-_ N/A _ _ NIA NIA <br /> Was sensor properly replaced after testing? N/A NIA NIA N/A <br /> Depth of water level from UDC bottom (in,) 6 6 6 <br /> Waft lime for water level to stabilize (hrmin) 0:10 0:to 0:10 0:10 <br /> Test start time 1:24 PM 1:24 PM 1:24 PM 1:24 PM <br /> Initial Probe Reading 1.5639 2.8023 3.2645 3.9307 <br /> Test end time 1:40 PM .- 1:40 PM 1:40 PM _ 1:40 PM <br /> Final Probe Reading 1.5855 2.8824 3.2639 3.93D8 <br /> Test duration (hr.-min) 0:16 0:16 0:16 0:16 <br /> Change In water level (t 0.0000 inches) 0.0016 _ 0.0001 -0.0006 -0.0001 ' <br /> PasslFall threshold (#0.0020Inches/}Hr.) ' . . 0.0020 0,0020 0.0020 0,0020 = <br /> TEST RESULT PASS PASS PASS PASS <br /> Comments: <br /> 2508 Walton Engineering.Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.