Laserfiche WebLink
AdML MEL <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, Califomia95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.siaov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br />L?ADA <br /> Facility Phone: Date: <br /> N FAST N EASY rb0` 209 931-6154 Aril 25, 2016 <br /> Facility Address: CERS ID: <br /> 10878 N HWY 99 , STOCKTON, CA 95212 10180717 <br /> Inspection Contact: Title: Phone: <br /> Bill Bilal Mana er (209) 931-6154 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION- O eratin Permit ! - UST FACILITY <br /> Consent For: Consent Given By: <br /> Inspection O Photos O Samples Bill Bilal, Mana er <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Jason Haase 07/01/2016 Dale Calea i 10/04/2016 <br /> Service Technician Manufacturer's Training <br /> VM1.06/08/16; VR,08/25/17 <br /> C =Cal'oma c e of agu etlons HSC=Health and Safety Code CFR= ode of FederalRegulations <br /> V=Violation R=Repeat violation Cos=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate ❑V ❑R n COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitorthe tank system ❑V ❑R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted ❑V ❑R ❑COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current ❑V ❑R ❑COS <br /> 105 HSC 25286(c) Current BOE number not submitted ❑V ❑R ❑COS <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD ❑V ❑R o COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ❑V ❑R ❑COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing ❑V ❑R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment ❑V ❑R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ❑V ❑R ❑COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ❑V ❑R ❑COS <br /> 112 HSC 25264.2 Failed to test spill containers annually ❑V ❑R ❑COs <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ❑V ❑R ❑COS <br /> 114 CCR 2636(1) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V ❑R ❑COS <br /> 115 CCR 2715(x) Failed to inform the EHD of a change of designated operator within 30 days ❑V ❑R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification n V ❑R ❑COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1000'of a public well ❑V u R ❑COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test ❑V ❑R ❑COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days ❑V ❑R ❑COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after ❑V ❑R ❑COS <br /> 121 CCR 2663 Failed to submittank lining certification within 30 days or to conduct proper tests ❑V ❑R ❑COS <br /> [122HSC 25299 Documents were falsified or misrepresented ❑V ❑R ❑COS <br /> CCR 2661 Permit to repair USTsystem not obtained ❑V ❑R oCOS <br /> CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V ❑R oCOS <br /> CCR 2712(f) Failed to submit a written response within 30 days of receivingan inspection report ❑V ❑R ❑COS <br /> HSC 25404(e)(4) Failed to report program data electronically ❑V ❑R ❑COS <br /> Page 1 of 6 <br />