My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
14800
>
2300 - Underground Storage Tank Program
>
PR0231600
>
COMPLIANCE INFO_1986-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:11 PM
Creation date
11/8/2018 9:48:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2008
RECORD_ID
PR0231600
PE
2361
FACILITY_ID
FA0000957
FACILITY_NAME
LATHROP GAS & FOOD MART*
STREET_NUMBER
14800
Direction
S
STREET_NAME
STATE ROUTE 99
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19702004
CURRENT_STATUS
02
SITE_LOCATION
14800 S HWY 99 RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\14800\PR0231600\COMPLIANCE INFO 1986-2008.PDF
QuestysFileName
COMPLIANCE INFO 1986-2008
QuestysRecordDate
8/30/2017 6:29:37 PM
QuestysRecordID
3613342
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
375
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATE 12/3�z1 <br /> PR# oa <br /> PAGE s <br /> PUBLIC HEALTH SERVICES SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DIVISION <br /> 304 E.Weber Ave.,Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility Name Fncou Facility Address�g00 S H(tnj .. Ril :f�oringir At <br /> Facilty Contact Ivo Title__kno✓ Phone <br /> UST#4 Product 1 0` tUL UST# S Product?,,,, uLUST# (o Product i e o UST# Product <br /> OVERFILL PREVENTION: U Audible/Visual ❑Mechanical Monitoring Pgnel: Veeder`i�bn{- T[S ZSD i <br /> PIPING SYSTEM: 11Gravity 0-1irressure ❑ Suction Violations: V Minor ❑ Major <br /> AUTOMATIC PUMP SHUT DOWN SATISFIES CCR 2636(g): ❑Yes I/No <br /> INSPECTION TYPE: pPoutine PAonitoring Certification oComplaint ❑Install ❑Removal EIRe air/Upgrade <br /> COMPANY NAME: TECHNICIAN NAME: t n PHONE <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 17 CCR 2650 Recording/reporting <br /> 1 HSC 25284 Permit to operateunauthorized release <br /> 2 CCR 2637 Secondary Cont.Testing 18--V-/—CCR 2632 (d) Monitoring &response plan <br /> 3 CCR 2711(b) & (c) Current State Forms A& B 19 CCR 2712 (i) Monitoring &response plan <br /> 4�HSC 25292.2 Certification of financial is on site <br /> responsibility and letter from 20_�t/ CCR 2712 (b) Maintenance& monitoring <br /> chief financial officerrecords <br /> 5 CCR 2630 (d) Continuous monitoring 21 CCR 2636 (f)(4) Annual line tightness test <br /> system for UST system 22_CCR 2630 (d) Annual line leak detector test <br /> 6 CCR 2636 (c)(1) All releases in secondary 23 CCR 2630 (d) Annual monitoring <br /> piping flow to a collection certification <br /> sump 24 CCR 2643 (d) Daily monitoring of suction <br /> 7 CCR 2636 (a) Secondary containment for piping that is not <br /> piping is waterproof continuously monitored <br /> 8 HSC 25291 (f) Automatic line leak 25 CCR 2643 (d) Triennial tightness test of <br /> detector(s) suction piping that is not <br /> 9 CCR 2636 (f)(1) Continuous monitoring continuously monitored <br /> system for underground 26 CCR 2643 (e) Biennial tightness test of <br /> piping gravity piping that is not <br /> 10 CCR 2632 (c)(2) Continuous monitoring continuously monitored <br /> system for UST 27 CCR 2662 Upgrade requirements for <br /> 11 HSC 25291(a)(2) Secondary containment for UST system <br /> UST is tight 28 CCR 2661 Permit to repair UST system <br /> 12 CCR 2636 (f)(1) Continuous monitoring 29_HSC 25286 (a) Permit to alter monitoring <br /> system for dispenser system system <br /> 13 CCR 2635(b)(1) Spill container 30 HSC 25298 (a) Illegal abandonment of UST <br /> 14_CCR 2635 (b)(2) Overfill prevention system system <br /> 15 CCR 2631 (a) Primary containment is 31 HSC 25298 (b) Permit to temporaril close <br /> product-tight UST system <br /> 16 HSC 25292.1 UST system is operated to 32 HSC 25298 (c) Permit to close US system <br /> prevent unauthorized release 33_ Violation(s)not list above <br /> EHD INSPECTOR: <br /> RECEIVED BY: TITLE: PHONE: <br />
The URL can be used to link to this page
Your browser does not support the video tag.